Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual page 520

Table of Contents

Advertisement

System board and components
▶ Wait until the firmware restore is completed.
BIOS or iRMC S6 firmware restore feature is executed at the same
time as the power cord is connected after the system board
replacement.
Depending on the configuration of your server the firmware restore
requires different time, see
duration during firmware restore" on page
18 - 38 minutes (systems with PFR feature).
Do not perform the following operations after connecting the power
cord. Please wait for the above time to elapse.
– Remove and reinsert the power cord
– Power button on/off
– Connecting and disconnecting other cables, etc.
▶ Check the status of the power-on indicator to verify if the firmware restore
was successful, see
firmware restore" on page
If the firmware restore is successfully completed, the power-on indicator is lit
white and the ID indicator is off.
If the power-on indicator is not lit white or the ID indicator is not off, an error
has occured. Disconnect and connect the power cord and try to boot up or
manually restore using the iRMC S6 Web interface. For details for manually
restore, see
"Manually restore an incomplete BIOS or iRMC S6 firmware
restore" on page
▶ After completion of the firmware restore, connect to the iRMC and check the
SEL log files, see
firmware
restore".
▶ Reboot the system by disconnecting and connecting the power cord. After
disconnecting the power cord, wait 60 seconds and connect it again.
"Switching on the server" on page
▶ Check that the Customer Production firmware version is restored to the
current BIOS or iRMC S6 version in the new system board using the BIOS
Setup Utility.
520
"States of power-on indicator and time
"States of power-on indicator and time duration during
541.
523.
"Manually restore an incomplete BIOS or iRMC S6
71.
Upgrade and Maintenance Manual
541:
RX2540 M7

Advertisement

Table of Contents
loading

Table of Contents