Operating conditions Ekip Synchrocheck, Ekip Com and Ekip Signalling function correctly:
System Interface Document 1SDH001140R0001.zip, describing how to use the Ekip Com communication modules correctly,
179 | © 2023 ABB | 1SDH001330R1002 - ECN000297030
• In the presence of auxiliary supply voltage
• With the circuit-breaker in the Racked-in position (if the CB version is withdrawable)
The limitations listed below apply in all the other cases:
Module\ Condi-
Ekip Synchro-
tion
check
Module power
Synchronism
supply absent
contact open
CB in Test
Synchronism: not
(1)(2)
position
available
CB in
Synchronism: not
DISCONNECTED
(1)
available
position
(3)
the description refers to the module when correctly on and with the CB in the indicated position
(1)
in the Test position, the Trip unit is connected to the modules and all information is available on
(2)
the display or via external communication
in the Racked-out position, connection and communication between Trip unit and modules is
(3)
interrupted. Information is not available/valid
due to voltage not connected to the internal sockets
(4)
(5)
see System Interface, INFORMATION WITH PROTECTION TRIP UNIT DISCONNECTED section (next
page)
the outputs only function correctly if configured as: input status (of module itself) or non-
(6)
communication with Trip unit. For all other configurations, the module forces the Outputs as per
Contact Type parameter (NO, NC).
is available in ABB library; the file contains:
Document
Description
Guidelines with details about how to put the communication modules
1SDH001140R0001.pdf
into service, with reference to the protocols and supporting documents
Table with the references of all the registers for parameters, controls,
1SDH001140R0001.xlsx
measurements, etc.
The .zip file contains the files for supplementing Ekip Touch in the available communication networks,
with the specific Ekip Com module and an IMPORTANT file with notes on how to use the files:
File
(1)(2)
ABBS0E7F.gsd + EkiDPB.bmp
Ekip_COM_EtherNetIP_M4_vx_xx.eds
Ekip_COM_DeviceNet_vx_xx.eds
ABBECxxxx_Ed1.icd
ABBECxxxx_Ed2.icd
GSDML-Vx.xx.xml
The files are also valid for the respective Redundant versions.
(1)
Check the Firmware version of your module so as to choose the file with the correct configuration.
(2)
Ekip Com
Communication:
absent
Communication:
active
(4)
Communication:
partially active
(4)
(5)
Protocol / Ekip Com module
File .gsd and module image for configuring Ekip Com
Profibus DP
File .eds for configuring Ekip Com EtherNet/IP
File .eds for configuring Ekip Com DeviceNet
File .icd for configuring Ekip Com IEC 61850
File .xml for configuring Ekip Com Profinet
ABB | SACE Emax 2
Ekip Signalling
2K
Ekip Signalling
Ekip Signalling
3T
4K
Ekip Signalling
10K
Output contacts:
Output contacts:
open
open
Inputs and output
Inputs and output
contacts: available
contacts: available
Inputs and output
Module power
contacts: partial
supply off (Output
available
contacts:: open)
(6)
TM
TM
Accessories
1 - Overview

Advertisement

Table of Contents
loading

Table of Contents