Charger Bosch C40-Li I Operating instructions 1 Technical data Technical data Input voltage 230 VAC / 50 Hz Starting current < 50 A Rated input current Max. 0.8 A (rms value) Power input 90 watts Nominal output voltage DC 6 V / 12 V Charging voltage 7.2 V / 14.4 V (±...
Page 5
Charger Bosch C40-Li I Operating instructions 2 Safety Before use your charger, please read all instructions carefully. CAUTION ◾ If the supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.
Charger Bosch C40-Li I Operating instructions ◾ This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Charger Bosch C40-Li I Operating instructions Overheating protection If the unit becomes excessively hot during charging, the output power and output current is automatically reduced to avoid damaging the unit. Standby and reverse polarity protection Mode Indicator Function Lights up when turned on and fully charged. Flashes while charging...
Charger Bosch C40-Li I Operating instructions Mode Output Indicator Operation Battery types supported Mode 7 0.5 A Press and hold the mode 6 V batteries. 25 % LED Push Mode button for 5 seconds, LED 13 flash at battery voltage on, 6 V &...
Charger Bosch C40-Li I Operating instructions flash alternatively, the charger will try to automatically detect the battery voltage (6 V or 12 V) in a complex measuring procedure. After 1-3 minutes, the charger will detect whether the battery is a 6 V or 12 V battery and switch to the appropriate 6 V mode or 12 V motorcycle mode.