Download Print this page

Husqvarna W 80P Workshop Manual page 20

Hide thumbs Also See for W 80P:

Advertisement

Repair instructions
Securely tighten the hose connector on the pump suc-
tion port.
Discharge hose installation (see Figure 3)
Use a commercially available hose (J). Use the hose
connector and the hose clamp provided with the pump.
It is best to use a short, large-diameter hose, because
that will reduce fluid friction and improve pump output.
A long or small-diameter hose will increase fluid friction
and reduce pump output.
Tighten the hose clamp securely (C) to prevent the dis-
charge hose from disconnecting under pressure.
20 - English
6.9 Sediment cup
6.9.1 To disassemble the Sediment cup
1. Move the fuel valve (A) to the OFF position.
OFF
Figure 1
2. Unscrew the sediment cup (B) using a wrench and
remove the O-ring (C).
B
Figure 2
6.9.2 To clean and examine the Sediment
cup
1. Wash the cup and O-ring in non-flammable solvent
and dry thoroughly.
2. Place the O-ring in the fuel valve then screw the
sediment cup into place and tighten securely.
3. Move the fuel valve to the ON position and check for
leaks. Replace the O-ring if there is any leakage.
A
ON
A