HP 8110A Service Manual page 103

150 mhz pulse generator
Hide thumbs Also See for 8110A:
Table of Contents

Advertisement

3- 56 Testing the HP 811 0Α
Internal Oscillator Period (continu ed)
TR Entry
Test
Limit
Actual
Limit
P
ass
Fail
Μίηίnlυm
Result
Μαxim υm
1 - 9
5 μ s
4.75μs
5 .25 μs
1 - 10
50 μs
47 .5 μs
52 .5 μ s
1 - 11
500 μ s
475 μ s
525 μ s
1-12
5 ms
4 .75 ms
5 .35 ms
1 - 13
50 ms
47 .5 ms
52 .5 ms
1-14
500 ms
475 ms
525 ms
Intern al
P
eriod Ji tter
Scope Un certainty factor
TR En t ry
T est
Limit
A
ctual
Limit
P
ass Fail
Minimum
R
esult
Μαασ m υm
6.2- 1
50 ns
50 ps
6.2- 2
500 ns
175 ps

Advertisement