Chapter 2 Preparations
1.13.4
Firmware(SDR) Updating
Apply SDR Firmware after the installation of internal simple UPS Control Kit.
SDR Update Tool CD-ROM is attached parts of the server.
To apply SDR Firmware, follow the procedure below.
1.
Connect a power code to the server.
2.
Wait for 40 seconds after AC power is supplied to the server.
3.
Turn on the server.
4.
Insert an "SDR Update Tool" CD-ROM to the optical disk drive and update SDR Firmware.
1.13.5
Precautions for operating with internal battery
Charge the battery before you start operation. You can check charging state and settings of internal battery
•
with EXPRESSSCOPE Engine 3 or NEC ESMPRO. For details, see the manual provided with each tool.
Following is the limitations when using internal battery.
•
Up to 4 hard disk drives can be installed.
High Temperature Resistant Kit cannot be mounted.
The backup device cannot be mounted on 3.5-inch additional bay (2).
Redundant power unit cannot be installed.
If errors are detected after you finished installation, confirm the mount procedure and confirm the cable of
•
internal battery is surely connected.
The setting to start shutdown when power supply abnormality occurs is enabled by default.
•
Express5800/T110i-S User's Guide
1. Installing Internal Optional Devices
81