Preset Mode - Toshiba LF620F Instruction Manual

Electromagnetic flowmeter converter
Hide thumbs Also See for LF620F:
Table of Contents

Advertisement

8.2.22 Preset Mode

The preset mode determines the function when the totalizer reaches the preset count.
The present mode can be set from the items shown below.
●Preset mode
Selection items
Note: If you set the preset mode to "50ms PLS" or "500ms PLS", you need to set the preset
You can check or change the preset mode as described below.
The following is an example to change the present mode from Output condition hold (HOLD)
to One-shot pulse output with pulse width of 50ms (50ms PLS).
Switch operation
STEP1
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
HOLD
50ms PLS
500ms PLS
count to 1, 2, 5, 25, 125 ×10
preset output timing may be shifted when the totalizer overflows.
Display example
K:PRESET C
1 PRST VAL
2 OUT MODE
3 EXIT
ESC
OUT MODE
HOLD
ESC
- 91 -
Preset mode
Holds the output value.
Outputs a one shot pulse of 50ms width.
Outputs a one shot pulse of 500ms width.
n
. (If you set a value that does not meet this condition, the
Select "OUT MODE" from the setting item
selection menu.
The current setting (HOLD in this example)
appears.
Then push
* Pushing
ESC
screen.
6 F 8 A 0 9 2 8
Description
.
returns you to the menu

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf622f

Table of Contents