6 F 8 A 0 9 2 8
(3) Remote selection of unidirectional flows multi-range with an external signal
Output (%)
125
100
Range 2
Range 1
0
4mA
Reverse direction
0
Forward direction
Flow rate
External signal
H level input
L level input
Range output No.1
ON
OFF
• Current output when fluid flows in reverse direction is the output low limit setting (any one of 2.4 /
3.2 / 4.0mA).
- 119 -