Alarm Message "Cabinet's Door Opened - Siemens SICHARGE UC Operating Instructions Manual

Table of Contents

Advertisement

Handling alarms and errors

9.3 Alarm message "Cabinet's Door Opened"

EMERGENCY OFF state
The EMERGENCY OFF function switches off the power supply of the charging cable. The
charging process is stopped immediately. The SICHARGE UC Dispenser switches to the safe
EMERGENCY OFF state. In the EMERGENCY OFF state, operation of the
SICHARGE UC Dispenser is no longer possible for safety reasons.
Cancel the EMERGENCY OFF state
NOTE
Eliminate the hazardous situation
First eliminate the hazardous situation. Only then cancel the EMERGENCY OFF state.
To cancel the EMERGENCY OFF state, reset the EMERGENCY OFF button on the
SICHARGE UC charging station.
9.3
Alarm message "Cabinet's Door Opened"
When you open the cabinet door of a SICHARGE UC Dispenser or the SICHARGE UC charging
station, the HMI shows the following alarm message.
"Housing door open" alarm message
When the EMERGENCY OFF pushbutton is pressed on the charging station, the HMI shows the
alarm message in full screen mode:
Figure 9-2  "Housing door open" alarm message
Alarm status "Cabinet's Door Opened"
When you open a cabinet door, the SICHARGE UC Dispenser automatically switches off the
power supply of the charging cable. The safety shutdown also ends any charging in progress.
The SICHARGE UC Dispenser switches into a safe state. When a cabinet door is open,
operation of the SICHARGE UC Dispenser is not possible.
96
SICHARGE UC Dispenser
Operating Instructions, 06/2023, A5E50235695-AE

Advertisement

Table of Contents