Siemens SICHARGE UC Operating Instructions Manual page 64

Table of Contents

Advertisement

Commissioning
7.1 Initial commissioning
Verification of electrical functionality
The service technician checks the following components and functions during initial
commissioning:
• Emergency stop switch
– Actuate the emergency stop switch
– Alarm message on HMI indicates emergency stop switch actuation
– Unlock emergency stop switch
– Alarm message on HMI is automatically reset
• Check the functionality of AC contactors and DC contactors and the feedback of the
contactors on the HMI (LED)
Checking the charging session
NOTE
The electric vehicle must have a low SoC (< 60%).
Connect the laptop to the charging station beforehand.
1. Connect the CCS plug with the electric vehicle
2. Switch on the "Cable check" mode at the charger
– "Cable check" HMI display
– The voltage rises to almost 500 V within a few seconds and then goes down to 0 V.
3. Switch on the "Pre-charge" mode at the charger
– "Pre-charge" HMI display
– Voltage ramps up to vehicle battery voltage
4. Switch on the "Current demand" mode at the charger
– "Charging" HMI display
– Current ramps up to meet the demand of the vehicle
5. End the session using the stop button on the HMI
– Charging process stops.
– "Charging completed" HMI display
NOTE
The behavior of the charging station depends on the electric vehicle.
• When the electric vehicle stops the charging process at 100%, the charging station stops.
• If the electric vehicle does not stop the charging process at 100%, the charging station
continues the charging process. The customer then has to stop the process.
64
SICHARGE UC Dispenser
Operating Instructions, 06/2023, A5E50235695-AE

Advertisement

Table of Contents
loading

Table of Contents