Siemens Sicharge CC AC22-MID Operating Manual

Siemens Sicharge CC AC22-MID Operating Manual

Hide thumbs Also See for Sicharge CC AC22-MID:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Sicharge CC AC22-MID

  • Page 2 SICHARGE Operating Manual MID Introduction Safety information SICHARGE Description Operation SICHARGE CC AC22 - MID SICHARGE Operating Manual MID Faults Appendix Operating Manual List of abbreviations 02/2022 A5E48572776-AD...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Introduction ............................4 Purpose of this documentation .................... 4 Conventions ........................4 Open-source software ......................5 Safety information ..........................6 General safety information ....................6 Safety during operation and charging .................. 7 Description ............................. 9 Charging station structure....................9 Operation .............................
  • Page 5: Introduction

    Introduction Purpose of this documentation This operating manual contains information for operating the SICHARGE CC AC22 charging station. The operating manual contains information on the prescribed use of the charging station. WARNING Failure to comply with the information in these operating instructions may result in the following: •...
  • Page 6: Open-Source Software

    Siemens accepts no liability for the use of the open-source software over and above the intended program sequence, or for any faults caused by modifications to the software.
  • Page 7: Safety Information

    Safety information General safety information This chapter contains important and generally valid information for preventing accidents or property damage that may occur during operation and use of the charging station. Read this chapter carefully and follow the safety regulations. This will minimize safety risks. The instructions in the documentation do not replace statutory safety instructions.
  • Page 8: Safety During Operation And Charging

    Safety information 2.2 Safety during operation and charging Safety during operation and charging The following description warns of additional hazards that must be considered when operating the charging station. Act according to the specified operating instructions, and observe the valid regional standards and regulations. Failure to follow safety instructions may result in hazardous situations that could cause death or serious injury.
  • Page 9 Safety information 2.2 Safety during operation and charging Charging cable and socket Defective connectors or cables may cause fire. Qualified personnel must shut down the unit and replace the damaged components immediately. Do not bend or squeeze the charging cable; do not run it over sharp edges, and use it only within the permissible temperature range.
  • Page 10: Description

    Description Charging station structure ① Status light ⑤ Charging connection type 2 ② HMI ⑥ Pushbutton ③ Viewing window for meter ⑦ Maintenance door ④ RFID reader ⑧ Option: Fixed charging cable Figure 3-1 Charging station structure SICHARGE Operating Manual MID Operating Manual, 02/2022, A5E48572776-AD...
  • Page 11: Operation

    Operation Status indicators Notes on operation The SICHARGE CC AC22 charging station is equipped with status indicators. Different colors and flashing signals indicate the current status of charging points 1 and 2. This signalizes to drivers if the charging station is available and what its status is. The display also directly shows the required information.
  • Page 12 Operation 4.1 Status indicators Status indicators The table below provides an overview of the LED status indicators of the charging points: Does not light up If the status indicator does not light up, this indicates an interruption to the power supply. If there is not a power failure, check the backup fuses.
  • Page 13: Display/Gui

    Operation 4.2 Display/GUI Display/GUI Start screen After power on or after a few seconds without operation command, the station will show the start screen. ① Charging point 1 ④ Drawn energy charging point 1 ② Status display charging point 1 ⑤...
  • Page 14 Operation 4.2 Display/GUI Operator guidance The user of the charging station is guided through the operating steps using graphics. Some displays also show text references. ① Primary language ② Secondary language Figure 4-3 Operator guidance SICHARGE Operating Manual MID Operating Manual, 02/2022, A5E48572776-AD...
  • Page 15: Charging

    Operation 4.3 Charging Status display of the charging points The status displays ② on the HMI have the following meanings for the charging points: Status display Meaning • Charging point available • Charging of an electric vehicle is possible Charging active Charging point reserved Charging point error Charging point inactive...
  • Page 16 Operation 4.3 Charging Start charging Proceed as follows to start charging: 1. Check if the required charging point is ready for operation: The status LED must light up green. 2. Use the left or right pushbutton to select the desired charging point. 3.
  • Page 17 Operation 4.3 Charging 8. The device locks the plug into the socket. 9. After the plug is locked successfully, the charging process starts automatically and the LED status indicator pulsates blue. The vehicle is now being charged. The plugs are still protected against unauthorized removal.
  • Page 18 Operation 4.3 Charging There are 3 different ways to terminate charging: Procedure with RFID card Proceed as follows to end the charging process with the RFID card: 1. Charging point selection: Press the pushbutton below the display and follow the instructions.
  • Page 19: Faults

    Faults Fault clearance Procedure in the event of a fault If the charging station experiences a fault, proceed as follows: 1. Check the display. The following options are available for diagnostics: – Screen maintenance status: Open the screen by pressing a button for five seconds (long press).
  • Page 20 Faults 5.1 Fault clearance – Screen out of order: The displayed error code (for example, #40-02-00) can only be used for diagnostics and fault clearance (e.g. with the help of the Service hotline). Figure 5-2 Screen out of order – Flash codes of the LED status indicator (see Status indicators (Page 10)) –...
  • Page 21 Faults 5.1 Fault clearance 2. You can find a selection of possible causes of faults and possible remedies in the table below. 3. If you are unable to rectify the fault yourself, contact the operator's service hotline. Cause Remedied by Solution Vehicle not connected Operator...
  • Page 22: Appendix

    The EC Declarations of Conformity are kept available for the responsible authorities at: Siemens AG Smart Infrastructure Distribution Systems Mozartstr. 31c 91052 Erlangen, Germany They are also available for download on the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/) website. SICHARGE Operating Manual MID Operating Manual, 02/2022, A5E48572776-AD...
  • Page 23: List Of Abbreviations

    List of abbreviations Abbreviations EVSE Electric Vehicle Supply Equipment RCCB Residual Current Circuit Breaker Graphical User Interface Graphical user interface Measurement Instruments Directive OCPP Open Charge Point Protocol RFID Radio-Frequency Identification Radio-frequency identification Schuko Socket outlet with grounding contact socket SICHARGE Operating Manual MID Operating Manual, 02/2022, A5E48572776-AD...

Table of Contents