14 DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED, CONT'D
FIGURE 1
Note. Maximum permissible
flue length is measured from
centre line of appliance flue
outlet to outside wall face.
FIGURE 2
Shows the flue required when measured from outside edge of turret to the outside face of the wall (to obtain cut length add 44mm)
Horizontal Flue Terminal
(600mm long) B Pack
Minimum
B Pack (Standard)
171
Plus 1 (1m D pack)
1121
Plus 2 (1m D pack)
2071
Plus 3 (1m D pack)
3021
Plus 4 (1m D pack)
3971
Plus 5 (1m D pack)
4921
Plus 6 (1m D pack)
5871
Plus 7 (1m D pack)
6821
Plus 8 (1m D pack)
7771
Plus 9 (1m D pack)
8721
Note; Telescopic flue B Pack or attached "D" pack extensions do not need to be cut between minimum and maximum values
shown above (except where specified). Horizontal Flue Terminal (600mm long) B Pack flue will require cutting on values below
maximum values shown in the table above.
If using the 2000mm D Pack , the maximum usable length per extension is 1950mm
If using the 500mm D Pack, the maximum usable length per extension is 450mm.
20
INSTALLATION
Edge of turret
to outside face of wall plus
44mm = ue length
A
100mm
REAR
Fit
to wall
NOTES
Centre of turret to edge of turret = 100mm
Turret has a ue insertion of 30mm
The compressed outer wall seal has protruding wall to seal mounting lip - 14mm
From centreline of turret to wall. Rear mount 155mm, side (including clearance) 200mm
Minimum & Maximum finished flue lengths obtainable (dimension 'A' +44mm)
Telescopic Flue B Pack
Maximum
Minimum
556
286
1506
1236
2456
2186
3406
3136
4356
4086
5306
5036
6256
5986
7206
6936
8186
7886
9000
8836
Edge of turret
to outside face of wall plus
44mm = ue length
A
REAR
Fit
to wall
inc. Stand
o Frame
Horizontal Flue
Terminal (1000mm long)
B Pack (Telescopic)
Maximum
Minimum
Maximum
484
601
1434
1551
1766
2384
2501
2716
3334
3451
3666
4284
4401
4616
5234
5351
5566
6184
6301
6516
7134
7251
7466
8084
8201
8416
9000
9000
9000
Edge of turret
to outside face of wall plus
44mm = ue length
A
SIDE
Fit
to wall
Minimum clearance 5mm
Flue length measured from outer terminal lip
to end of outer ue
A + 44mm
Horizontal Flue Terminal
(1000mm long) B Pack
(Telescopic) Cut 75mm
Minimum
Maximum
816
526
741
1476
1691
2426
2641
3376
3591
4326
4541
5276
5491
6226
6441
7176
7391
8126
8341
9000
9000