Appendix B: As4428 Abs Front Panel Configuration Labelling - Haier Ampac ZoneSense PLUS Operation Instructions Manual

Table of Contents

Advertisement

8 Appendix B: AS4428 ABS Front Panel Configuration Labelling

ZONE
CONFIGURATION
BELL
1
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
2
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
3
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
4
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
A
5
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
6
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
7
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
8
NORM / AVF / NON / SELF / AT1 / AT2 / AT3 / AT4
B
EOL VALUE
3K3 / 4K7 / 6K8 / 10K / CAP
MCP ZONE
1 / 2 / 3 / 4 / 5 / 6 / 7 / 8
No LAMs
1 / 2 / 3 / 4 / 5 / 6 / 7 / 8
FOR FULL INSTALLATION DETAILS OF ZONESENSE PLUS "ADD ON's" REFER TO MAN1565
Instructions to Installer
A, B, D, F & H Using a permanent marking pen cross out the conditions that do not apply.
C, E, & G Using a permanent marking pen cross (X) the box for the option that is set for the Zone.
A
Indicates the configuration of each Zone Normal (NORM), AVF, Non-latching (NON), Self resetting (SELF) Agent Trigger/s AT1 / AT2 / AT3 / AT4.
B
Indicates what EOL value has been selected, what Zone has the FACP MCP been mapped to, and the number of Mimics controlled by the FACP.
C
Indicates what Zones controls what Main Card Outputs.
D
Indicates if Zone Alarm ( A ), Fault ( F ) or Isolate ( I ) controls the designated relay, as well as any 16 input or Card input or, any switch / indicator switches and
if the ACF Isolate, Reset function or Latching is set.
E
Indicates what Zones control what Sounders.
F
Indicates the type of Agent Release fitted, the type and duration of delay and the number of Local Control Stations fitted. ( Not Applicable )
G
Indicates what Zone/s activates what Fan/s.
H
Indicates what Zone/s Inhibit what Fan/s and the type of wire Function and whether or not latching and / or ACF Isolate is set.
WARN
ACF
ASE
ALARM
B ALARM 1
B ALARM 2
RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 RELAY 6 RELAY 7 RELAY 8
S Y S
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
C
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
INPUT
SWITCH
ACF ISOL
Y / N
Y / N
RESET
Y / N
Y / N
LATCHING
Y / N
Y / N
SOUNDER
SOUNDER
1
2
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
D
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
A / F / I
AGENT RELEASE
AUTO DELAY - SECS
Y / N
Y / N
Y / N
Y / N
Y / N
Y / N
MANUAL DELAY - SECS
Y / N
Y / N
Y / N
Y / N
Y / N
Y / N
PRESSURE SWITCH
Y / N
Y / N
Y / N
Y / N
Y / N
Y / N
No OF LCS'S
SOUNDER
SOUNDER
SOUNDER
SOUNDER
SOUNDER
SOUNDER
FAN 1
FAN 2
3
4
5
6
7
8
G
E
SOLENOID / PYROGEN / METRON
0 / 15 / 30 / 60 /
3 / 4 / 5
3 / 4 / 5
F
0 / 15 / 30 / 60 /
Y / N
Y / N
NO / NC / NA
Y / N
Y / N
1 / 2 / 3 / 4
MAN1564-3
FAN 3
FAN 4
H
INHIBIT ZONES
3 / 4 / 5
3 / 4 / 5
FUNCTION
Y / N
Y / N
LATCHING
Y / N
Y / N
ACF ISOLATE
34