Optional) Antifreezing - Huawei FusionCol8000-C210 User Manual

In-room chilled water smart cooling product
Hide thumbs Also See for FusionCol8000-C210:
Table of Contents

Advertisement

FusionCol8000-C210 In-room Chilled Water Smart
Cooling Product
User Manual
Figure 5-23 Shutdown
Step 2 Tap Submit. If the device is successfully shut, the system displays a message,
indicating that the command is successfully triggered.
Step 3 Turn off the general switch of the unit. For a unit with dual power supplies, turn
off both the active and standby power switches.
Step 4 (Optional) If the power supply needs to be disconnected for maintenance or for a
long period, turn off the smart cooling product switch in the power distribution
frame (PDF).
----End

5.9 (Optional) Antifreezing

Context
If the FusionCol8000-C will be idle for a long time, ensure that the circulation
water inside the system has a temperature no lower than 3°C, or has used
antifreeze liquid, otherwise, the heat exchanging pipes of the smart cooling
product may freeze up and crack. If the water temperature does not meet the
requirement, drain all water out of the FusionCol8000-C.
Procedure
Step 1 Remove the plugs from the drainage needle valve 1 and 2 of the heat exchanger,
to drain water naturally until no water flows out.
Issue 05 (2022-12-15)