Performance Specifications - Mitsubishi Electric MELSEC iQ-F Series User Manual

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

2.3

Performance Specifications

The following table lists the performance specifications.
Items
CC-Link IE Field
Station type
Network Basic
Maximum number of connectable stations
Number of stations occupied by a remote station
Maximum number of link points per network
Maximum number of link points per
station
UDP port number used in the cyclic transmission
UDP port number used in the automatic detection of connected
device
Transmission
specifications
Network topology
*3
Hub
Connection cable
General-
Transmission
purpose
specifications
Ethernet
communication
Protocol type
Number of connections
*3
Hub
Connection cable
Number of ports
Number of occupied I/O points
Applicable CPU module
Applicable engineering tool
Number of connectable modules
2 SPECIFICATIONS
18
2.3 Performance Specifications
*1
Master
station
Remote
station
Data transmission speed
Interface
Maximum station-to-station distance
Overall cable distance
Number of cascade
100BASE-TX
connections
*5
100BASE-TX
Data transmission speed
Communication mode
Transmission method
Interface
Maximum segment length
Number of cascade
100BASE-TX
connections
10BASE-T
*8
*5
100BASE-TX
10BASE-T
GX Works3
Certificate Configuration Tool for FX5-ENET
Specifications
Master station
32
1 to 4
RX
2048
RY
2048
RWr
1024
RWw
1024
RX
2048
RY
2048
RWr
1024
RWw
1024
RX
64/128/192/256
*2
RY
64/128/192/256
RWr
32/64/96/128
RWw
32/64/96/128
61450
Master station: An unused port number is assigned automatically.
Remote station: 61451
100Mbps
RJ45 connector
100m
Depends on the system configuration
For the number of the connectable stages when using a switching hub,
check with the manufacturer of the switching hub used.
Star topology
Hubs with 100BASE-TX ports
Ethernet cable of category 5 or higher (STP cable)
100/10Mbps
Full-duplex or half-duplex
Base band
RJ45 connector
100m (length between hub and node)
2 levels maximum
4 levels maximum
MELSOFT connection, SLMP server (3E/1E frame), socket
communication, simple CPU communication, BACnet/IP
Total of 32 connections
(Up to 32 external devices can access one FX5-ENET module at the
same time.)
Hubs with 100BASE-TX or 10BASE-T ports
Ethernet cable of category 5 or higher (STP cable)
Ethernet cable of category 3 or higher (STP/UTP cable)
*11
2
8 points
• FX5UJ CPU module (From the first)
• FX5U CPU module (Ver. 1.110 or later)
• FX5UC CPU module
• FX5UJ CPU module: GX Works3 (Ver. 1.060N or later)
• FX5U/FX5UC CPU module: GX Works3 (Ver. 1.050C or later)
Ver. 1.00A or later
1
*4
can be used.
*3
*6
*7
*7
*9
*10
can be used.
*12
(Ver. 1.110 or later)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-enetFx5-u-enet-e09r736

Table of Contents