Buffer memory address
Decimal
Hexadecimal
8760, 8761
2238H, 2239H
8762, 8763
223AH, 223BH
8764
223CH
8765
223DH
8766, 8767
223EH, 223FH
8768
2240H
8769
2241H
8770
2242H
8771
2243H
8780 to 8791
224CH to 2257H
8800 to 8811
2260H to 226BH
8820 to 8831
2274H to 227FH
8840 to 8851
2288H to 2293H
8860 to 8871
229CH to 22A7H
8880 to 8891
22B0H to 22BBH
8900 to 8911
22C4H to 22CFH
8920, 8921
22D8H, 22D9H
8922, 8923
22DAH, 22DBH
8924
22DCH
8925
22DDH
8926, 8927
22DEH, 22DFH
8928
22E0H
8929
22E1H
8930
22E2H
8931
22E3H
8940 to 8951
22ECH to 22F7H
8960 to 8971
2300H to 230BH
8980 to 8991
2314H to 231FH
9000 to 9011
2328H to 2333H
9020 to 9031
233CH to 2347H
9040 to 9051
2350H to 235BH
9060 to 9071
2364H to 236FH
9080, 9081
2378H, 2379H
9082
237AH
9083
237BH
9084
237CH
9100 to 9104
238CH to 2390H
9120 to 9124
23A0H to 23A4H
9140 to 9144
23B4H to 23B8H
Name
BACnet communication
Object ID
AnalogOutput 1
PresentValue
OutOfService
Reliability
Value set value
Write setting
Write control
Update counter
Units
BACnet communication
Same configuration as BACnet
AnalogOutput 2
communication AnalogOutput 1
BACnet communication
Same configuration as BACnet
AnalogOutput 3
communication AnalogOutput 1
BACnet communication
Same configuration as BACnet
AnalogOutput 4
communication AnalogOutput 1
BACnet communication
Same configuration as BACnet
AnalogOutput 5
communication AnalogOutput 1
BACnet communication
Same configuration as BACnet
AnalogOutput 6
communication AnalogOutput 1
BACnet communication
Same configuration as BACnet
AnalogOutput 7
communication AnalogOutput 1
BACnet communication
Same configuration as BACnet
AnalogOutput 8
communication AnalogOutput 1
BACnet communication
Object ID
AnalogValue 1
PresentValue
OutOfService
Reliability
Value set value
Write setting
Write control
Update counter
Units
BACnet communication
Same configuration as BACnet
AnalogValue 2
communication AnalogValue 1
BACnet communication
Same configuration as BACnet
AnalogValue 3
communication AnalogValue 1
BACnet communication
Same configuration as BACnet
AnalogValue 4
communication AnalogValue 1
BACnet communication
Same configuration as BACnet
AnalogValue 5
communication AnalogValue 1
BACnet communication
Same configuration as BACnet
AnalogValue 6
communication AnalogValue 1
BACnet communication
Same configuration as BACnet
AnalogValue 7
communication AnalogValue 1
BACnet communication
Same configuration as BACnet
AnalogValue 8
communication AnalogValue 1
BACnet communication
Object ID
BinaryInput 1
PresentValue
OutOfService
Reliability
BACnet communication
Same configuration as BACnet
BinaryInput 2
communication BinaryInput 1
BACnet communication
Same configuration as BACnet
BinaryInput 3
communication BinaryInput 1
BACnet communication
Same configuration as BACnet
BinaryInput 4
communication BinaryInput 1
Initial value
Read, write
0
Read
0
Read
0
Read, write
0
Read, write
0
Read, write
0
Read, write
0
Read, write
0
Read
0
Read
0
Read
0
Read
0
Read, write
0
Read, write
0
Read, write
0
Read, write
0
Read, write
0
Read
0
Read
0
Read
0
Read, write
0
Read, write
0
Read, write
APPX