Configuration Page; Alignment Page; Event Log Page - Motorola Canopy Subscriber Module User Manual

Table of Contents

Advertisement

CONFIGURATION PAGE

The Configuration webpage contains information and configurable parameters pertaining to the
operation of the product. The following are the parameters and their descriptions.
Parameter
Custom RF Frequency
Scan Selection (SM) List
Lan 1 IP
Lan 1 Subnet Mask
Default gateway
Color Code
SM Power Up Mode with
No 802.3 Link
Webpage Auto Update
Display Only Access
Full Access

ALIGNMENT PAGE

The Alignment webpage contains information for aligning the subscriber module to an access point.
The operator can toggle between Operational Mode and Alignment Mode on this webpage.
The webpage will display the mode of the subscriber module. If a subscriber module is in
Alignment Mode for longer than 15 minutes, it will automatically switch to Operational Mode.
Click the Enable Alignment Mode ON or Disable Alignment Mode OFF buttons to switch between
the two modes.
The LED Bar Graph reflects the received signal strength from the access point. The more LEDs
"lit " from left to right, the stronger the received signal. The colors used in the LED Bar Graph do
not indicate anything other than to differentiate each position. While in Alignment Mode, the
information displayed on the LED Bar Graph can be observed on the subscriber unit physically
through the LED indicators. The information at both places is the same.

EVENT LOG PAGE

This page contains information that is recorded from the subscriber module for troubleshooting
purposes. Click the "Clear Event Log" button to clear the log.
Description
Determines which frequencies the subscriber module will scan. The
default is to scan all frequencies.
Determines the IP address of the subscriber module through the
Ethernet cable. The default value is 169.254.1.1
Determines the subnet mask for the subscriber module. The default
value is 255.255.0.0
Determines the default gateway for the subscriber module. The
default value is 169.254.0.0
This parameter will determine what Access Point the Subscriber
Module will register on. The Access Point and Subscriber Module
must have the same color code for registration to occur. The range
for this parameter is 0 to 254. The default value is 0.
Determines which mode the subscriber module will be in when power
is applied and it is not connected to any networked device. The two
modes are alignment mode or operational mode. The default value is
power up in operational mode.
Determines how often the webpages will refresh automatically. The
parameter is measured in seconds. The default value is 0, which will
cause a refresh to never happen.
Enter a password to make the status of the pages Display Only.
The default value is no password
Enter a password to allow full access (view and change) to the
webpages.. The default value is to have no value.
Page 11