Panasonic DVCPRO50 Service Manual page 53

Hide thumbs Also See for DVCPRO50:
Table of Contents

Advertisement

Item
Set value
SUPER
No.
No.
DISP.
P44
-88
T R1 1B
Q44
|
-32
|
-4
P45
-31
T R1 2B
Q45
|
0
|
40
P46
-31
T R1 3B
Q46
|
0
|
31
P47
-31
T R2 3A
Q47
|
0
|
31
P48
-31
T R2 2A
Q48
|
0
|
40
P49
-88
T R2 1A
Q49
|
-32
|
-4
P50
-88
T R2 1B
Q50
|
-32
|
-4
P51
-40
T R2 2B
Q51
|
0
|
31
P52
-31
T R2 3B
Q52
|
0
|
31
P53
0
IC READ
Q53
1
2
P60
0
VITERBI MODE
Q60
1
2
3
Setting contents and
SUPER
outline function explanation
DISP.
-88
The initial values for six of the seven tap coefficients of the adaptive
equalization filter, excluding the fixed center tap, are set for the R1
|
-32
head. The tap coefficient values after adaptive equalization filter
convergence at the time of standard tape playback are read out and
|
set.
-4
• Read-out is possible only at the time of PLAY, REC.
-31
|
0
|
40
-31
|
0
|
31
-31
The initial values for six of the seven tap coefficients of the adaptive
|
equalization filter, excluding the fixed center tap, are set for the R2
0
head. The tap coefficient values after adaptive equalization filter
|
convergence at the time of standard tape playback are read out and
31
set.
-31
• Read-out is possible only at the time of PLAY, REC.
|
0
|
40
-88
|
-32
|
-4
-88
The initial values for six of the seven tap coefficients of the adaptive
|
equalization filter, excluding the fixed center tap, are set for the R2
-32
head. The tap coefficient values after adaptive equalization filter
|
convergence at the time of standard tape playback are read out and
-4
set.
-40
• Read-out is possible only at the time of PLAY, REC.
|
0
|
31
-31
|
0
|
31
OFF
The following data are read out from the EQ200 IC. However, there
SINGLE
are limitations according to the mode.
CONT
Data which can be read-out only at the time of PLAY, REC
ENV L1
ENV L2
T L1 3A
T L1 2A
T L1 1B
T L1 2B
T L2 3A
T L2 2A
T L2 1B
T L2 2B
T R1 3A
T R1 2A
T R1 1B
T R1 2B
T R2 3A
T R2 2A
T R2 1B
T R2 2B
Data which can be read-out only at the time of EJECT,
STANDBY-OFF
VCO L
VCO R
0: No read-out
1: Read-out each time the SET button is pressed.
2: Read-out is performed once every second.
• The setting is held until exit from PB ADJUST.
OFF
Setting whether Viterbi decoding is to be used for detection of
PR4
playback data or not
EPR4
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
AUTO
ENV R1
ENV R1
T L1 1A
T L1 3B
T L2 1A
T L2 3B
T R1 1A
T R1 3B
T R2 1A
T R2 3B
INF-44
BACK
Remarks
-UP
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
No
Use for electrical adjustment
No
Use for electrical adjustment