Application Download; Led Display Indications - Motorola IRRInet-M DC Owner's Manual

Remote terminal unit
Table of Contents

Advertisement

Failure Type
RAM FAIL
ROM FAIL
FLASH FAIL
CREATE FAIL
REAL TIME CLOCK FAIL
INTERNAL CLOCK FAIL
BREAKPOINT FAIL
XTAL RATE CHANGE FAIL
USER REQUEST FAIL
APPL_VER_LT_SYSTEM_VER
(Application version less than System version)
CONF_VER_LT_SYSTEM_VER
(Configuration version less than System version)
GENERAL_HEAP_CRT_FAIL
(Heap- create failed)
GENERAL_ADAP_CRT_FAIL
(Adaptor- create failed)
GENERAL_LINK_CRT_FAIL
(Link- create failed)
GENERAL_MTE_ALLOC_FAIL
(MTE Allocate failed- not enough memory)

Application Download

For information on downloading an application to the IRRInet-M unit, see the ACE3600 STS
User Guide.

LED Display Indications

A 5 × 4 matrix of LEDs is used for diagnostics and testing of the unit (see Figure 3). The top
row indicates to which page or toggle (CPU, IO1, IO2, IO3, Page 4, Page 5) the LED panel is
set. To advance from one page to another, press the push-button once quickly. The first
depression of the push-button activates the display. Subsequent short depressions of the push-
button advance the display to the next page: CPU > IO1 (I/O Page 1-DI) > IO2 (I/O Page 2-
DO) > IO3 (I/O Page 3-DO) > Page 4 (User Application Controlled).
Note that Page 5 (Hardware Test Controlled) can only be accessed via the Hardware Test
utility of the STS, and not by pressing the push-button.
In each page, the LEDs have different functions, as described in the charts below.
Not all LEDs are relevant in all IRRInet-M models.
LEDs
CM3
RX3
CM3+RX3
TX3
CM3+TX3
RX3+TX3
CM3+RX3+TX3
MON
CM3+MON
RX3 + MON
RX3+CM3+MON
MON+TX3
MON+TX3+RX3
MON+TX3+RX3+CM3
CM2+MON
Description
5

Advertisement