2-10. SIDE-001 BOARD, SIDE-002 BOARD
Note 1: The SIDE-001 board, SIDE-002 board and SIDE-004 board
are repair parts as a unit of three boards together, whose volt-
age adjusted at the factory.
Therefore, if it is necessary to replace one of the boards of
SIDE-001 board, SIDE-002 board or SIDE-004 board, be sure
to replace three boards at the same time.
3 two screws (M1.7) (L = 4.0 mm)
Note 2: When tightening screws, tighten
the below torque value.
tightening torque:
4 SIDE-001 board
capsule side
5 two screws (M1.7) (L = 4.0 mm)
Note 2: When tightening screws, tighten
the below torque value.
tightening torque:
6 SIDE-002 board
8 shield plate
capsule side
SIDE-002 board side
Turn over.
connector
side
7 Draw the wire out of gap the SIDE-002
board and microphone frame.
SIDE-001 board side
1 Remove the three solders
of connector wire.
(See Fig. G)
2 Remove the two solders
of SIDE-002 board wire.
(See Fig. G)
connector side
< Fig. G >
Note 3: Set the wires so that they do not crossover.
–
connector
connector
wire [black]
wire [white]
Pass the wire a gap the SIDE-002 board
and microphone frame.
microphone frame
Gap.
–
C-100
–
connector side
SIDE-002 board
wire [black]
SIDE-002 board
wire [orange]
connector
wire [red]
SIDE-001 board
connector side
–
SIDE-002 board
13