the FPG if no longer wanted. For other File Services issues, use the CLI showfs, showvfs, showvfs
commands (and the associated set and stop commands) to investigate and solve issues.

host

Displays Adaptive Optimization issues
Checks that all PD classes that exist on any node-pair are found on all node-pairs
Checks that FC Fabric connected host ports are configured to support Persistent Ports
Checks that the FC switch ports are configured for NPIV support
Checks that FC Fabric connected host partner ports are found on same FC SAN
Checks that VLUNs are visible to their configured host through more than one node

Format of Possible host Exception Messages

Host <portID> "Port failover state is <failoverstate>, port state is <state>"
Host <portID> "Port not connected to fabric like <portID>"
Host <portID> "Port not configured as host like <portID>"
Host <portID> "Port not FC like <portID>"
Host <portID> "Port state is <state>, not ready like <portID>"
Host <portID> "Port WWN not found on FC Fabric attached to <portID>"
Host <portID> "Host port connected to FC Fabric switch port without NPIV support"
Host <portID> "Host is not seen by multiple nodes, only seen from node <nodeID>"

host Example 1

Component -------Summary Description-------- Qty
Host
Ports not configured symmetrically
Component -Identifier- ------------Detailed Description------------
Host
Port:0:1:1

host Action 1

Use the CLI showport, showport -par, and controlport commands to configure port 0:1:1
for point mode (fabric connect) or configure port 1:1:1 to loop mode (for direct connect).
showport -par 0:1:1 1:1:1
N:S:P Connmode ConnType CfgRate MaxRate Class2
0:1:1 host
1:1:1 host

host Example 2

Component ------Summary Description------- Qty
host
Hosts not seen by multiple nodes
Component -Identifier- ------------------Detailed Description-------------------
host
testhost

host Action 2

Use CLI showvlun -v and showhost commands to determine what issue is reported. If the host
is defined with only connections from one node, use the CLI createhost -add command to
add host connections for an additional to the host definitions. If the host is defined with ports from
Port not connected to fabric like Port:1:1:1
loop
auto
8Gbps
point
auto
8Gbps
Host is not seen by multiple nodes, only seen from node 3
1
UniqNodeWwn VCN
disabled disabled
disabled disabled enabled n/a
disabled disabled
disabled disabled enabled n/a
1
Troubleshooting Storage System Components
IntCoal
TMWO
Smart_SAN
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

3par storeserv 7000c

Table of Contents