4 Installation and Commissioning
4.3.7

Loading the STEP 7 project into the S7 CPU

Requirement:
The STEP 7 V17 project has already been installed and retrieved (see
4.3).
The IO-Link master has already been configured (see
Proceed as follows:
Start the TIA Portal.
Open the project view.
Open the "IOL_READ_WRITE_DATA" project.
In the project navigation:
Select "PLC_S7_1500 [CPU 1513-1 PN]"
Right-click and select:
"Download to device > Hardware and software"
Select the suitable PG/PC interface in the "Extended download to device"
dialog window. As soon as loading is possible, the "Download" button will be
enabled.
Click the "Download" button.
Check the messages in the "Load preview" dialog and if required, enable the
actions in the "Action" tab. As soon as loading is possible, the "Download"
button will be enabled.
Click the "Download" button.
The loading process is executed. Then the "Load events" dialog is opened.
In this dialog you can check whether the loading process was successful and
select possible other actions.
Click on the "Finish" button.