16. ELECTRICAL CONNECTION

The electrical installation must be performed by
a qualified electrician. The electrical connections
must comply with local indoor installation regu-
lations and must not be altered.
NOTE
Please follow these precautions
• Before connecting, check that the present
mains voltage and frequency correspond with
the data on the nameplate.
• Observe the applicable, country-specific, lo-
cal regulations of the relevant electricity sup-
ply authorities.
ImPOrTANT
Danger of fire, explosion and death
• Take care during installation with con-
sideration for any leakage current.
Each appliance comes with an appli-
ance-specific wiring diagram. This contains
the technical specifications (electrical rating,
voltage, amperage etc.).
Unless otherwise specified, our appliances
are delivered without mains cables. The en-
gineer must use a flexible cable that meets
the minimum requirements of cable type
HO7RN-F with rubber insulation and fulfills
EEC 73/23.
Connect power cord to the connection ter-
minal using a cable relief, in accordance with
the enclosed electrical diagram.
Once the machine has been connected and
the function switched on, you should check
that the mains voltage does not fluctuate
more than 10% from the rated voltage.
Pans with agitators contain frequency con-
verters with interference elimination filters.
When starting up the machine, a brief leak-
age current can result in earth leakage cir-
cuit breakers connected to the machine be-
ing tripped.
If the boiling pan is connected to a residual
current device (RCD), this should be of class
A and have a breaking current of 300mA for
optimum operational reliability.
If testing of insulation resistance shall be
performed during installation, the frequen-
cy converter have to be disengaged before
testing.
34
INSTALLATION INSTRUCTIONS | SmART LINE BOILINg PAN

16.1 Potential equalisation

The appliance must be connected to a
point indicated on a potential equalisa-
tion system with a minimum conductor
cross section of 10 mm².
When installing multiple appliances, connect
them all together through potential equalisation.
1 6-mm lug
2 m6 nut
3 m6 threaded bolt
4 m6 spring washer
5 m6 washers

16.2 Phase sequence

When connecting electrical cable(s) check that
the tilting motor is moving in the right direction.

16.3 Tilting function

Follow the symbols on the panel for the tilting
function. (See Operating Instructions.):
16.3.1
Testing the tilting function:
Press the button Control switch On/Off (see Fig.
23). Control current to the pan is now switched
on. Press the button briefly to tip the pan and
check that the movement corresponds with the
symbol. If this is not the case, turn two phases
on the incoming cable.
Warning!
The tilting device and other vital parts of the ma-
chine can be damaged if the machine's move-
ment does not correspond with the symbols.