Motorola MSF 5000 Instruction Manual page 209

Hide thumbs Also See for MSF 5000:
Table of Contents

Advertisement

MSF
5000
Instruction Manual
Chapter
4
Alignment
Alignment Procedures
NOTE
If
the
station is
a
trunked station
with
a
Console
Priority
Option
(C115) installed, continue
with
step
4.
Otherwise, proceed
to step
5.
4.
Verify
the
receive audio at
Line
4
on the system connector is at the desired
phone line level.
The typical phone line level
is from
0
dBm
to -10
dBm.
If
not,
set the
desired level
by adjusting
EEPOT
d.
5.
Deactivate all activated
MUXbus
bits.
6.
Set the
PL Dis/Xmit
switch
to the
center (normal) position.
Decoded Receive Audio Adjustment
The following procedure
adjusts
the
decoded receive audio
level
for stations
containing
the
Secure
Encryption Option (C331, C388, C794, C795,
or
C797). Before
performing this procedure, make
sure the
level of Line
2
is adjusted to the same
relative level
(0
dB)
as the
clear receive audio level.
NOTE
The Line
2
level must
be adjusted before
performing
this procedure.
1.
Inject
a
mV
RF
receive signal, modulated
with
a
secure
(digitally
encrypted)
1
kHz
tone at
3.9
kHz
deviation into
the
receiver antenna
connector on the
Junction
Box.
NOTE
The encryption source must
be
programmed
with
the
same
encryption key
as the
station. Refer to
Chapter
2
-
Operation for additional information.
2.
Verify
the
outbound receiver audio between
Line
2
(+)
and
Line
2
(-) is
0
dB
relative
to the
clear
wireline audio level.
The
clear
wireline audio level setting was
set
up in
the
Receive Wireline
Audio
Adjustment procedure
or the
maximum allowable phone line level,
whichever
is less.
If
not, adjust
EEPOT
0.
3.
Remove
the
RF
signal from
the antenna
connector on the
Junction
Box.
68P81092E04
3/19/94
4-43
MSF
5000
Instruction Manual
Chapter
4
Alignment
Alignment Procedures
NOTE
If
the
station is
a
trunked station
with
a
Console
Priority
Option
(C115) installed, continue
with
step
4.
Otherwise, proceed
to step
5.
4.
Verify
the
receive audio at
Line
4
on the system connector is at the desired
phone line level.
The typical phone line level
is from
0
dBm
to -10
dBm.
If
not,
set the
desired level
by adjusting
EEPOT
d.
5.
Deactivate all activated
MUXbus
bits.
6.
Set the
PL Dis/Xmit
switch
to the
center (normal) position.
Decoded Receive Audio Adjustment
The following procedure
adjusts
the
decoded receive audio
level
for stations
containing
the
Secure
Encryption Option (C331, C388, C794, C795,
or
C797). Before
performing this procedure, make
sure the
level of Line
2
is adjusted to the same
relative level
(0
dB)
as the
clear receive audio level.
NOTE
The Line
2
level must
be adjusted before
performing
this procedure.
1.
Inject
a
mV
RF
receive signal, modulated
with
a
secure
(digitally
encrypted)
1
kHz
tone at
3.9
kHz
deviation into
the
receiver antenna
connector on the
Junction
Box.
NOTE
The encryption source must
be
programmed
with
the
same
encryption key
as the
station. Refer to
Chapter
2
-
Operation for additional information.
2.
Verify
the
outbound receiver audio between
Line
2
(+)
and
Line
2
(-) is
0
dB
relative
to the
clear
wireline audio level.
The
clear
wireline audio level setting was
set
up in
the
Receive Wireline
Audio
Adjustment procedure
or the
maximum allowable phone line level,
whichever
is less.
If
not, adjust
EEPOT
0.
3.
Remove
the
RF
signal from
the antenna
connector on the
Junction
Box.
68P81092E04
3/19/94
4-43