Kenwood CS-1022 Instruction Manual page 13

Hide thumbs Also See for CS-1022:
Table of Contents

Advertisement

C S - 1 0 2 2 , 1 0 2 1 , 1 0 1 2
CHOP:
The display cannot be synchroniz-
ed w i t h the input signal since the
chopping signal becomes the trig-
ger source.
C H 1 :
Sweep is triggered by channel 1 signal
regardless of vertical MODE selection.
CH2:
Sweep is triggered by channel 2 signal
regardless of vertical MODE selection.
LINE:
Sweep
is
( 5 0 / 6 0 Hz).
EXT:
Sweep is triggered by signal applied to EXT
TRIG INPUT jack © .
@
TRIG MODE
Three-position lever switch; selects triggering mode.
AUTO:
Triggered sweep operation when trigger
signal is present, automatically generates
sweep (free runs) in absence of trigger
signal.
NORM:
Normal triggered
trace is presented when a proper trigger
signal is not applied.
X-Y:
X-Y operation. Channel 1 input signal pro-
duces vertical deflection (Y axis). Channel
2 input signal produces horizontal deflec-
tion (X axis).
This operates regardless vertical MODE
selection.
@
VARIABLE Control
Fine sweep time adjustment. In the fully clockwise
(CAL) position, the sweep time is calibrated.
©
SWEEP TIME/DIV
Horizontal coarse sweep time selector.
Selects calibrated sweep times of 0.2 /ts/div to 0.5 s/
div
in 2 0 steps (CS-1021, CS-1012... 0.5 ^s/div to
0.5 s/div in 19 steps) when sweep time VARIABLE
control ®
is set to CAL position (fully clockwise).
(§)
«<• POSITION, PULLx 10 MAG
Rotation adjusts horizontal position of trace. Push-pull
switch selectsx 10 magnification (PULLx 10 MAG)
when pulled out; normal when pushed in.
triggered
by
line
voltage
sweep
operation.
No
CS-1020, 1 0 1 0
@
TRIG MODE
Three-position lever switch; selects triggering mode.
AUTO: Triggered
sweep
signal
is present,
sweep (free runs) in absence of trigger signal.
NORM: Normal triggered sweep operation. No trace is
presented when a proper trigger signal is not
applied.
X-Y:
X-Y operation. Vertical input signal produces
vertical deflection (Y axis). EXT TRIG input
produces horizontal deflection (X axis).
®
VARIABLE Control
Fine sweep time adjustment. In the fully clockwise
(CAL) position, the sweep time is calibrated.
For X-Y operation, this control serves as the X axis
gain adjustment.
©
SWEEP TIME/DIV
Horizontal coarse sweep time selector.
Selects calibrated sweep times of
0.5 s/div
in 2 0 steps (CS-1010... 0.5 /xs/div to
0.5 s/div in 19 steps) when sweep time VARIABLE
control ®
is set to CAL position (fully clockwise).
(§)
POSITION. PULLx 10 M A G
Rotation adjusts horizontal position of trace. Push-pull
switch selectsx 10 magnification (PULLx 10 MAG)
when pulled out; normal when pushed in.
For X-Y operation, this control serves as the X axis
position control.
operation
when
trigger
automatically
generates
0.2 /ts/div
to
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-1021Cs-1012Cs-1020Cs-1010

Table of Contents