Pr.338 Communication operation command source
Pr.339 Communication speed command source
*1
Torque bias selection 1
X42
*1
Torque bias selection 2
X43
*1
P/PI control switchover
X44
*1
Second brake sequence open completion
BRI2
*1
Trace trigger input
TRG
*1
Trace sampling start/end
TRC
*1
Power failure stop external
X48
*1
Sequence start
SQ
*1
Fault clear
X51
*1
Cumulative pulse monitor clear
X52
Cumulative pulse monitor clear (control terminal
*1
X53
option)
JOG forward rotation command
*1
JOGF
JOG reverse rotation command
*1
JOGR
*1
NET position pulse clear
CLRN
*1
Forward rotation command
STF
*1
Reverse rotation command
STR
*1
Inverter reset
RES
*1
PID forward/reverse action switchover
X64
*1
PU/NET operation switchover
X65
*1
External/NET operation switchover
X66
*1
Command source switchover
X67
*1
Simple position pulse train sign
NP
*1
Simple position droop pulse clear
CLR
*1
DC feeding operation permission signal
X70
*1
DC feeding cancel signal
X71
*1
PID P control switchover
X72
*1
Second PID P control switchover
X73
*1
Magnetic flux decay output shutoff
X74
*1
Proximity dog
X76
*1
Pre-charge end command
X77
*1
Second pre-charge end command
X78
*1
Second PID forward/reverse action switchover
X79
*1
Second PID control valid
X80
*1
SSCNET III communication disabled
X85
*1
Sudden stop
X87
Forward stroke end
*1
LSP
*1
Reverse stroke end
LSN
*1
Emergency stop
X92
*1
Torque control selection
X93
Control signal input for main circuit power supply
*1
X94
MC
*1
Converter unit fault input
X95
*1
Converter unit fault (E.OHT, E.CPU) input
X96
*1
Low-speed forward rotation command
RLF
*1
Low-speed reverse rotation command
RLR
*1
Use Pr.178 to Pr.189 (Input terminal function selection) to assign the function to an input terminal. (Refer to
*2
When Pr.77 = "2", Pr.162 setting can be changed during operation. The new setting is applied after stop. Until the inverter has stopped, the
previous setting of the interface for the operation command and the speed command in the Network operation mode is valid.
Downloaded from
ManualsNet.com
search engine
0: NET
1: EXT
0:
1:
2:
0:
NET
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
Combined
EXT
Combined
EXT
EXT
EXT or NET*
EXT
Combined
EXT
NET
EXT
NET
EXT
EXT
EXT
NET
NET
EXT
NET
EXT
EXT
NET
EXT
NET
EXT
EXT
EXT
EXT
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
External
NET
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
EXT
Combined
EXT
EXT
EXT
EXT
NET
EXT
EXT
EXT
EXT
EXT
EXT
5.9 (D) Operation command and frequency command
Remarks
1:
2:
EXT
Pr.414 = "1": Valid when there
is EXT or NET input.
Pr.414 = "2": EXT
page
521.)
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
405

Hide quick links: