 Parameter write enabled during operation (Pr.77 = "2")
• These parameters can always be written.
• The following parameters cannot be written during operation even if Pr.77 = "2". To change the parameter setting value,
stop the operation.
Pr.
23
48
49
60
61
66
71
79
80
81
82
83
84
90 to 94
95
96
135 to 139
178 to 196
248
254
261
289
291
292
293
298
313 to 322
329
373
406
414
415
418
419
420, 421
450
451
453
454
Downloaded from
ManualsNet.com
Name
Stall prevention operation level compensation
factor at double speed
Second stall prevention operation level
Second stall prevention operation frequency
Energy saving control selection
Reference current
Stall prevention operation reduction starting
frequency
Applied motor
Operation mode selection
Motor capacity
Number of motor poles
Motor excitation current
Rated motor voltage
Rated motor frequency
(Motor constant)
Online auto tuning selection
Auto tuning setting/status
(Electronic bypass sequence parameter)
(Input and output terminal function selection)
Self power management selection
Main circuit power OFF waiting time
Power failure stop selection
Inverter output terminal filter
Pulse train I/O selection
Automatic acceleration/deceleration
Acceleration/deceleration separate selection
Frequency search gain
(Extended output terminal function selection)
Digital input unit selection
Encoder position tuning setting/status
High resolution analog input selection
PLC function operation selection
Inverter operation lock mode setting
Extension output terminal filter
Position command source selection
(Electronic gear)
Second applied motor
Second motor control method selection
Second motor capacity
Number of second motor poles
search engine
Pr.
455
Second motor excitation current
456
Rated second motor voltage
457
Rated second motor frequency
458 to 462
(Second motor constant)
463
Second motor auto tuning setting/status
507, 508
(Display/reset ABC relay contact life)
541
Frequency command sign selection
560
Second frequency search gain
561
PTC thermistor protection level
570
Multiple rating setting
574
Second motor online auto tuning
598
Undervoltage level
Power failure stop external signal input
606
selection
639, 640
(Brake sequence)
641, 650, 651
(Second brake sequence)
660 to 662
Increased magnetic excitation deceleration
SF-PR slip amount adjustment operation
673
selection
699
Input terminal filter
702
Maximum motor frequency
706, 707, 711,
712, 717, 721,
(PM motor tuning)
724, 725, 1412
738 to 746, 1413
(Second PM motor tuning)
Second motor low-speed range torque
747
characteristic selection
Low speed range torque characteristic
788
selection
800
Control method selection
819
Easy gain tuning selection
858
Terminal 4 function assignment
859
Torque current/Rated PM motor current
Second motor torque current/Rated PM motor
860
current
862
Encoder option selection
868
Terminal 1 function assignment
977
Input voltage mode selection
998
PM parameter initialization
999
Automatic parameter setting
1002
Lq tuning target current adjustment coefficient
1105
Encoder magnetic pole position offset
1292
Position control terminal input selection
1293
Roll feeding mode selection
1348
P/PI control switchover frequency
5.7 (E) Environment setting parameters
1
2
Name
3
4
5
6
7
8
9
10
347
5. PARAMETERS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents