Upgrading The Rom On Board (When No Macro Function Is Used); Preparation Before Adjustment; Endec Cpu (Bkma-7010), Enc Cpu (Bkma-7020), And Dec Cpu (Bkma-7030) - Sony MAV-70 Manual

Multi access video and audio server
Hide thumbs Also See for MAV-70:
Table of Contents

Advertisement

1-7. Upgrading the ROM on Board (When no macro function is used)

1-7. Upgrading the ROM on Board (When no macro function is used)
This section describes to upgrade the ROM on the board by entering commands.
Follow this procedure if the upgrading (in Section 1-6) cannot be performed using a macro function.

1-7-1. Preparation before Adjustment

n
When upgrading DPC CPU (SY-253 board) of a loop-connected extension unit, open "Service: Config"
screen from the menu of the extension unit and set "Single".
After upgrading is completed, return the menu to the former setting.
Preparation
1. Perform in the same procedure as for preparation in Section 1-6.
2. Activate Tera Term, select "Control" _ "Macro" from the top menu, set the following item.
Transmit delay : 0 msec/char
0 msec/line

1-7-2. ENDEC CPU (BKMA-7010), ENC CPU (BKMA-7020), and DEC CPU (BKMA-7030)

n
The display screen is an example of DEC CPU.
1. Activate Tera Term.
2. Press the [ENTER] key.
("MON>" is displayed.)
"
MON>
3. Enter "VER" and confirm the CPU name and current software version.
MON> VER "
[DEC] Version : 1.000, Nov 18 1998
Compiled at 10 : 12 : 31
MON>
4. Enter "FLASH ERASE 1".
(Software sector 1 in the old version is erased.)
MON> FLASH \ ERASE \ 1 "
FLASH ERASE ERASE 1 . . . OK
MON>
5. Enter "RES".
(The program in the old version stops and the CPU is reset.)
MON> RES "
*** MONGER (MONitor/debugGER) Version 0.32 Copylight (C) 1993-96 Sony Corp. ***
(Nov 7 1996/16:42:56)
[RES]
1-16 (E)