Station Status Control - Toshiba V Series User Manual

Admap-5m an712 module
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

Chapter 5 Application Interface
5.9.5

Station status control

5
80
<Function>
To control a specified AN712 module
<Message format>
B y t e a d d r e s s
+ 0 0 ( 0 x 0 0 )
C o m m a n d
+ 4 ( 0 x 0 E )
+ 6 ( 0 x 0 )
+ 8 ( 0 x 2 )
R e s p o n s e
+ 0 0 ( 0 x 0 0 )
+ 4 ( 0 x 0 E )
+ 6 ( 0 x 0 )
+ 8 ( 0 x 2 )
<Response status>
0x0000
Normal end
0x0203
Request inhibited in the present state
<Note>
• A software initialize request may be made only when all the message requests to the
AN712 module have been completed. Requesting software initialize produces a result
equivalent to switching the AN712 module on/off so that, if existing message requests
have not been completed yet, there will be no notice of their completion.
5
' A N 7 1 2 M G R Q '
A u x i l i a r y i n f o r m a t i o n ( 0 x 0 )
S t a t i o n s t a t u s c o n t r o l i n s t r u c t i o n ( 0 x 8 C 0 y )
R e q u e s t s t a t u s ( 0 x 0 )
y : s t a t u s c o n t r o l i n s t r u c t i o n v a l u e
I n r i n g r e q u e s t ( ) / o f f - r i n g r e q u e s t ( 2 ) / o n l i n e
r e q u e s t ( 3 ) / s t a n d b y r e q u e s t ( 4 ) / s t a r t r e q u e s t
( 0 x E ) / s o f t i n i t i a l i z e r e q u e s t ( 0 x F )
5
' A N 7 1 2 M G R Q '
A u x i l i a r y i n f o r m a t i o n ( 0 x 0 )
S t a t i o n s t a t u s c o n t r o l r e s p o n s e ( 0 x 8 C 8 y )
R e s p o n s e s t a t u s ( e r r o r c o d e )
model 3000 ADMAP-5M AN712 Module User's Manual
0
0