CHAPTER 2. Installation of RRH-P4
2.6 Connecting cable between RRH and Antenna
2.6.1 Connecting Feeder Line
Follows the steps below to connect the feeder line.
Caution for connecting and disconnecting Feeder Line Connector
- Check whether the system is turned off before connecting or disconnecting a
- When connecting the feeder line between RRH-P4 RF port and RF antenna,
2-16
4.0
RRH-P4
Figure 2.12 RRH-P4 Feeder Line Connection Diagram
feeder line connector to or from the RRH-P4 RF port and the RF antenna.
each port and the feeder line connector should be tighten by 14.46 lbf.ft
(200 kgf.cm) torque to minimize influence of PIMD.
RF Antenna
'B'
'A'
© SAMSUNG Electronics Co., Ltd.