Huawei BTS3900 GSM Commissioning Manual page 29

Hide thumbs Also See for BTS3900 GSM:
Table of Contents

Advertisement

BTS3900 GSM
Commissioning Guide
Tool
GSM mobile station for test
Crossover cable
Serial port cable
Straight screwdriver
General light emitting diode
(LED)
Site Information
Before the commissioning, you must obtain the following information on the BTS3900:
l
l
BTS3900 Board Software
Before the commissioning, download the matching software for the boards in the BTS3900
cabinet to the maintenance computer.
The software for the boards in the BTS3900 is as follows:
l
l
l
l
Issue 03 (2008-07-15)
Information on BTS networking and related configuration, including BTS type,
transmission mode, networking mode, and cell configuration
BTS3900 data configured at the BSC
DRFU software
GTMU software
GATM software
PMU software
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
2 General Requirements for BTS3900 Commissioning
Qua
Description
ntity
Two
Mandatory. The mobile station is used to perform the
dialing test and to check whether the antenna system
is properly connected.
The requirements for the GSM mobile station for test
are as follows:
Installed with the SIM card
l
Registered with the HLR on the network side
l
One
Mandatory. The crossover cable is used to connect
the maintenance computer to the BBU.
One
Mandatory. The serial port cable is used when you
query the board IP address. The auxiliary cables are
listed as follows:
One debug cable
l
One extended serial port cable
l
One
Mandatory. The straight screwdriver is used to
remove the crossover cable.
When removing the RJ45 connector of the crossover
cable from the ETH port, you must use a straight
screwdriver to press the RJ45 connector and then
remove the RJ45 connector.
Two
Optional. The general LED is used to determine the
RX or TX end of the E1/T1 cable.
2-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

V300r008

Table of Contents