Radio set with 7-day room temperature controller

Advertisement

Engineering
Room controller
REV24RF..:
Mounting the room
controller REV24RF..
on the wall
Stand for REV24RF..
Receiver RCR10/868:
11 / 18
Siemens
Building Technologies
· Place the room unit in the main living room by considering the following aspects (wall
mounting or free placement using stand).
· The distance to the receiver may not exceed 20 meters or 2 floors.
· Choose the place of installation so that the sensor can capture the air temperature in
the room as accurately as possible without being adversely affected by direct solar
radiation or other heat or cooling sources (about 1.5 meters above the floor for wall
mounting).
· Choose the location to ensure largely interference-free transmission. Observe the
following:
Do not mount on metallic surfaces.
-
Do not mount near electrical cables and equipment like PCs, TVs, microwaves, etc.
-
Do not mount near larger metallic structures or constructional elements with fine
-
metal meshes such as special glass or special concrete.
· Use the DIP switches to adapt the control behavior.
· Recalibrate the temperature sensor (see "Sensor calibration") if the displayed room
temperature does not match the room temperature measured.
· Mount the unit base for the REV24RF.. in the desired location.
· See also "Mounting and commissioning notes".
· Attach the base first and then slide the unit in the base from top to bottom. You can
mount the base on most commercially available recessed conduit boxes or directly on
the wall.
· When mounting on a wall, make sure there is sufficient clearance above the unit to
allow for removing and refitting the unit.
· See the installation instructions printed on the stand.
· Place the REV24RF.. in the desired location.
.
· Install the receiver close to the controlled unit if possible.
· Choose the location to ensure largely interference-free reception. Observe the
following for mounting the room unit:
Do not mount in a control panel.
-
Do not mount on metallic surfaces.
-
Do not mount near electrical cables and equipment like PCs, TVs, microwaves, etc.
-
Do not mount near larger metallic structures or constructional elements with fine
-
metal meshes such as special glass or special concrete.
· Make sure the location is dry and protected against splash water.
· You can mount the unit on most commercially available recessed conduit boxes or
directly on the wall.
Room temperature controller radio set REV24RF../SET
min.
10 cm