PROGRAMMING
Trouble
Incorrect
counterweight
settings
Gate drops too
quickly
Gate Descent time
is not set to the
desired speed.
Motor overload is
tripped
Gate raises
partially then falls
Low battery voltage
Gate arm does not
Gate Up position
rise to the desired
improperly
vertical position
programmed.
Gate arm rests
above or below
Incorrect horizontal
the desired
buffer setting
horizontal position
Contact
Digital Contacts
Open/Closed in the
not operating as
horizontal position
intended
functionality is
reversed.
SIG-QG-21-01
Version: A
Cause
Verify correct
counterweighting.
Verify gate descent time
is programmed a lower
value than intended.
Determine if yellow Motor
Overload LED is
illuminating during
operation.
Verify correct
counterweighting.
Verify battery voltage is
dropping below the 11
VDC minimum during
operation.
Verify Gate Up position is
not programmed to the
desired vertical angle
(position).
Check the horizontal
buffer setting.
Verify contact
programming setting.
Action
Adjust as necessary to achieve
proper horizontal and vertical torque
values
Refer to the programming section of
this manual and reprogram the Gate
descent time to the desired fall time.
Clear gate of any obstructions and
ensure the drive train rotates freely.
Adjust as necessary to achieve
proper horizontal and vertical torque
values.
Ensure a minimum of 11 VDC is
sustained at all times on terminals
B12 and N12 while the gate is
ascending.
Refer to the programming section of
this manual and reprogram the Gate
Up position to the desired vertical
angle as defined by the site-specific
conditions. (*Note- the Gate Up
position can only be set to a vertical
angle ranging from 70 to 88
degrees).
Adjust the horizontal buffer so the
gate arm is resting in the level
position and the gate arm height is
properly set in reference to the
crown of the roadway.
It may be necessary to raise or
lower the mechanism on the mast to
achieve the proper gate height
above the roadway and to ensure
the gate arm is level.
In the programming sequence
toggle from the Open in the
Horizontal position to Closed in the
Horizontal position (or vice versa)
state for the respective contact.