Mitsubishi Electric NZ2EHG-T8N User Manual page 24

10/100/1000m industrial switching hub
Table of Contents

Advertisement

5. System Reference
Table 5.2. Installation environment requirements
Item
Operating ambient temperature 0 to 50°C
Storage ambient temperature
Ambient humidity
Floating dust particles
Corrosive gases
Line-noise
Noise
Electrostatic
immunity
discharge
immunity
Vibration
Sweep resistance
resistance
Shock resistance
Grounding
Installation location
23
-10 to 60°C
10 to 90%RH (No condensation)
Tolerant of small amounts (non excessive)
None
AC line/2kV, Signal line/1kV (JIS C61000-4-4 Level 3, IEC61000-4-4 Level
3)
Contact discharge/4kV (JIS C61000-4-2 Level 2, IEC61000-4-2 Level 2)
Air discharge/8kV (JIS C61000-4-2 Level 3, IEC61000-4-2 Level 3)
10 to 57Hz/ half amplitude 0.15mm,57 to 150Hz/2.0G
40minutes each in X, Y, and Z directions
(JIS C60068-2-6-compliant, IEC60068-2-6-compliant)
15G, sine half-wave pulse for 11ms each in X, Y, and Z directions
(JIS C60068-2-27-compliant, IEC60068-2-27-compliant)
Ground the FG terminal to the protective ground conductor.
Inside a control panel
Specification