Safety instructions
1-12
1.8
Ensuring EMC of the completely assembled system
Note: The completely assembled system with the welding transformer
.
complies with prEN 50240, the EMC product standard for resistance
welding systems, and EN 55011 (October 1997), EMC product family
standard class A, group 2, rated current > 100 A.
D Only for industrial applications.
D Safe clearance from residential areas y 30 m.
D Safe clearance to communication systems (wireless, telephone) y 10 m.
D Cable length of mains feeder y 10 m.
D Interference suppression measures: When switchgear cabinet doors are
open, operation of radio devices or cell phones is permitted only beyond
a safe clearance of y 2 m.