7.5.8

Chairman Only mode

Set the Mode switch at the CPSU successively in the Test and Chairman Only mode.
Measure the DC-voltage via M33 related to M8 (0V).
Mode switch
Test mode
Override mode
7.5.8.1
Delegate microphone temporary off when pressing the priority button at the Chairman unit(s) (TRMO)
Connect a Delegate and a Chairman unit to the CPSU.
Set the Microphone switch of the chairman unit (see Priority button) in position 0.
Press the microphone button on the Delegate unit. The light ring illuminates.
Press the priority button of the Chairman unit. The light ring goes out.
Release the priority button. The microphone and light ring of the Delegate unit goes on again.
Measure the DC-voltage for each step via M33 related to M8 (0V).
Microphone switch
position 0
position 0
7.5.8.2
Delegate microphone permanently off when pressing the priority button at the Chairman unit(s) (RMO)
Connect a Delegate and a Chairman unit to the CPSU.
Set the Microphone switch of the chairman unit (see Priority button) in position 1.
Press the microphone button on the Delegate unit. The light ring illuminates.
Press the priority button of the Chairman unit. The light ring goes out.
Release the priority button. The microphone and light ring of the Delegate unit stays off.
Measure the DC-voltage for each step via M34 related to M8 (0V).
Microphone switch
position 1
position 1
7.5.8.3
Priority switch (only for Chairman units)
Connect a Chairman unit to the CPSU.
Press the Priority button at the Chairman Unit.
The Light-ring must illuminate now.
A chime tone will now be emitted depending on the position of the chime switch. This switch is accessible by
removing the cable relief bracket (0=no chime at priority, 1=chime at priority).
Set the microphone switch (located near the chime switch) successively in position 0 and 1.
Keep the Priority button pressed and measure the DC-voltage via M5, related to M2 (GND).
Mode switch
n.a.
n.a.
Bosch Security Systems | 2005-01| 3922 880 21112
M33
> 4.0V (ORM is activated)
< 0.5V (ORM is inactive)
Priority button
on
off
Priority button
on
off
Microphone switch
0 = permanent OFF
1 = temporary OFF
M33
> 4.0V (TRMO- is inactive)
< 0.5V (TRMO- is activated)
M34
< 0.5V (RMO is inactive)
> 4.0V (RMO is activated)
M5
> 13.35V (RMO activated)
between 8.7V and 10.11V (TRMO- is activated)