Rear view

a Protruding lid for holding when
moving the tumble dryer (see
arrows)
b Accessories for external drainage of
condensed water: hose clip, adapter
and hose holder
c Hose for external drainage of
condensed water
d Mains connection cable
e Communication module slot
(Feature not available in Australia
and New Zealand at time of printing)

Transporting the dryer

To manoeuvre the dryer out of its
packing case to its installation site, hold
it by
– the front feet
– and the protruding lid at the back of
the appliance.
Only transport the dryer as
shown in the following illustrations.
74
If transporting the dryer at an
angle, only tip towards the left side.
If the tumble dryer has not been
transported as described, then it
must be left to stand for at least 1
hour before it is connected to the
electricity supply.
Otherwise the heat pump can be
damaged.