3. Distributor type MULTI F DX (3 phase)
Combination
Outdoor Air
Capacity Index
Temperature
TC
(kBtu/h(%))
(°CDB)
kW
10
7.22
12
7.12
14
7.02
16
6.92
18
6.82
20
6.72
21
6.67
23
6.56
24
25
6.46
(50%)
27
6.36
29
6.27
31
6.17
33
6.07
35
5.98
37
5.88
39
5.79
41
5.69
43
5.59
46
5.41
10
5.65
12
5.57
14
5.50
16
5.42
18
5.34
20
5.26
21
5.22
23
5.14
19
25
5.06
(40%)
27
4.98
29
4.90
31
4.83
33
4.75
35
4.68
37
4.60
39
4.53
41
4.45
43
4.37
46
4.24
Notes:
1. Capacities are based on the following conditions.
Main Piping Length 5m, Branch Piping Length 5m
Level difference : 0m
Indoor Air Temperature (°CWB)
14.0
16.0
18.0
PI
TC
PI
TC
kW
kW
kW
kW
0.92
7.55
0.93
7.93
0.96
7.46
0.97
7.84
1.00
7.36
1.01
7.75
1.05
7.26
1.05
7.66
1.09
7.16
1.10
7.55
1.14
7.06
1.15
7.45
1.17
7.01
1.17
7.40
1.21
6.91
1.22
7.30
1.26
6.80
1.27
7.19
1.31
6.70
1.32
7.09
1.36
6.60
1.37
6.99
1.41
6.50
1.41
6.89
1.45
6.41
1.46
6.79
1.50
6.31
1.51
6.70
1.55
6.22
1.56
6.60
1.61
6.12
1.61
6.51
1.67
6.02
1.67
6.41
1.72
5.92
1.73
6.31
1.81
5.76
1.81
6.15
0.74
5.91
0.75
6.21
0.77
5.84
0.78
6.14
0.80
5.76
0.81
6.07
0.84
5.68
0.85
5.99
0.88
5.61
0.89
5.91
0.92
5.53
0.92
5.83
0.94
5.48
0.94
5.79
0.98
5.40
0.98
5.71
1.02
5.32
1.02
5.63
1.05
5.25
1.06
5.55
1.09
5.17
1.10
5.47
1.13
5.09
1.14
5.39
1.17
5.01
1.17
5.32
1.21
4.94
1.21
5.24
1.25
4.87
1.25
5.17
1.29
4.79
1.30
5.09
1.34
4.72
1.34
5.02
1.39
4.64
1.39
4.94
1.46
4.51
1.46
4.82
19.0
19.5
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
0.93
8.13
0.94
8.24
0.94
0.97
8.05
0.98
8.15
0.98
1.02
7.96
1.02
8.06
1.02
1.06
7.86
1.07
7.97
1.07
1.11
7.76
1.11
7.87
1.12
1.16
7.66
1.16
7.77
1.17
1.18
7.61
1.19
7.71
1.19
1.23
7.51
1.24
7.61
1.24
1.28
7.40
1.28
7.51
1.29
1.33
7.30
1.33
7.40
1.33
1.37
7.20
1.38
7.30
1.38
1.42
7.10
1.43
7.20
1.43
1.47
7.00
1.47
7.10
1.47
1.52
6.90
1.52
7.00
1.52
1.57
6.81
1.57
6.91
1.57
1.62
6.71
1.62
6.81
1.62
1.67
6.62
1.68
6.72
1.68
1.73
6.52
1.73
6.62
1.73
1.82
6.36
1.82
6.47
1.82
0.75
6.36
0.75
6.45
0.75
0.78
6.30
0.79
6.38
0.79
0.82
6.23
0.82
6.31
0.82
0.85
6.15
0.86
6.24
0.86
0.89
6.07
0.90
6.16
0.90
0.93
6.00
0.94
6.08
0.94
0.95
5.95
0.95
6.04
0.96
0.99
5.87
0.99
5.96
1.00
1.03
5.79
1.03
5.87
1.03
1.07
5.71
1.07
5.79
1.07
1.11
5.63
1.11
5.71
1.11
1.14
5.55
1.15
5.63
1.15
1.18
5.48
1.18
5.56
1.18
1.22
5.40
1.22
5.48
1.22
1.26
5.33
1.26
5.41
1.26
1.30
5.25
1.30
5.33
1.31
1.35
5.18
1.35
5.26
1.35
1.39
5.10
1.39
5.18
1.39
1.46
4.98
1.46
5.06
1.46
2. TC : Total Capacity (kW)
PI : Power Input
(kW)
Heat pump 50Hz/R410A
22.0
24.0
TC
PI
TC
PI
kW
kW
kW
kW
8.75
0.95
9.14
0.95
8.67
0.99
9.06
0.99
8.59
1.03
8.98
1.04
8.49
1.08
8.89
1.08
8.40
1.13
8.80
1.13
8.29
1.18
8.69
1.18
8.24
1.20
8.64
1.21
8.14
1.25
8.54
1.26
8.03
1.30
8.43
1.30
7.93
1.34
8.32
1.35
7.82
1.39
8.22
1.40
7.72
1.44
8.11
1.44
7.62
1.48
8.01
1.49
7.52
1.53
7.91
1.53
7.42
1.58
7.82
1.58
7.33
1.63
7.72
1.63
7.24
1.68
7.63
1.69
7.15
1.74
7.54
1.74
7.00
1.82
7.40
1.82
6.85
0.76
7.15
0.76
6.79
0.79
7.09
0.80
6.72
0.83
7.03
0.83
6.65
0.87
6.96
0.87
6.57
0.91
6.88
0.91
6.49
0.94
6.80
0.95
6.45
0.96
6.76
0.97
6.37
1.00
6.68
1.01
6.29
1.04
6.60
1.05
6.20
1.08
6.51
1.09
6.12
1.12
6.43
1.12
6.04
1.15
6.35
1.16
5.96
1.19
6.27
1.20
5.89
1.23
6.19
1.23
5.81
1.27
6.12
1.27
5.74
1.31
6.04
1.31
5.67
1.35
5.97
1.36
5.59
1.40
5.90
1.40
5.48
1.46
5.79
1.46
_ 22