1. Multiple piping type MULTI F

1.1 Power supply

Type
Outdoor unit
A2UW14GFA0 [MU2M15 UL2]
A2UW16GFA0 [MU2M17 UL2]
A3UW18GFA0 [MU3M19 UE2]
A3UW21GFA0 [MU3U21 UE2]
Heat Pump
A4UW24GFA0 [MU4M25 U42]
A4UW27GFA0 [MU4M27 U42]
A5UW30GFA0 [MU5M30 U42]
A5UW40GFA0 [MU5M40 UO2]
External wiring procedure
- The power supply work is needed only to the outdoor unit. The power supply to the indoor unit is conducted through the
transmission wiring. Therefore, the power supply work can be carried out at just one place of the outdoor unit. It will
contribute to simplify the work procedure and to save cost.
- Wiring cable size must comply with the applicable local and national code.
Power supply
Circuit breaker
Earth wire
Capacity[kBtu/h(kW)] Circuit breaker capacity
14.0 (4.10)
16.0 (4.69)
18.0 (5.27)
21.0 (6.15)
24.0 (7.03)
27.0 (7.91)
30.0 (8.79)
38.2 (11.2)
Outdoor unit
Power supply
15A
20A
220-240V, 1Ø, 50Hz
25A
30A
[Indoor unit]
Heat Pump
50Hz/R410A