Hägglunds DUc Drive unit | Installation
Bosch Rexroth AB, Version 06.2020, RE 15326-WA

7 Installation

7.1 Installation directives

If the Drive Unit is to work properly it must be installed in accordance with
these instructions. The conditions the unit will operate in must be taken into
consideration.
Improper installation, not following the instructions in this manual and in the
attached technical documentation, may affect the function and/or the service life
of the Drive Unit. It is important that the safety precautions in this manual always
are followed.
Position the Drive Unit:
• on a firm level foundation to avoid vibrations.
• to ease maintenance and service (see 7.3: Positioning the Drive Unit).
• protected from weather, airborne sprays, heavy contaminations and radiated heat.
• to ensure free ventilation for cooling purposes for the electric motor and the air-
oil cooler. See Fig. 17 and Fig. 36.
• to minimize pipe runs.
Clamp each pipe in the pipe run separately and attach it to a firm foundation to
avoid vibration. The hydraulic connections from the Drive Unit must always be
fitted to the piping with hoses. If air-oil cooler is mounted at a location other than
on the Drive Unit, it must be considered that the cooler will start without notice
and has sharp edges.
Danger while transporting or lifting Hägglunds Drive Unit due to heavy weight!
Danger to life, risk of injury or serious injuries and risk of damage to equipment
▶ Do not stand under hanging load.
▶ Use only lifting equipment adapted to the weight of the Drive Unit (check
rating plate inside the cabinet).
▶ Centre of gravity is high, see label on plastic cover of cabinet.
▶ Do not lift the Drive Unit with hydraulic fluid in the tank, or with the front bar
disassembled.
▶ Do not lift the Drive Unit with main electric motors installed unless the motors
are preassembled at delivery.
▶ Always use the number or lifting points, seen in Fig. 13, Fig. 14, Fig. 15, Fig. 16,
when lifting the Drive Unit.

7.2 Lifting methods

Lifting with fork lift
See 6.2: Lifting the packed Drive Unit section lifting with fork lift.
Lifting with ropes/chains
The Drive Unit shall be lifted without main electric motors and cooler unless they
are assembled at delivery. See data sheet
delivery