2-17. Setup Menu (F-Series)

2-17-2. F-Series Items

The F-series items contain the following items.
In the "Settings" columm of the table, the factory default settings are indicated by an enclosing box.
No.
ITEM
F01
AUDIO NR IN SP
MODE
F02
EMERGENCY TAPE
PROTECTION
F13
TRACKING
CONTROL VIA
SEARCH DIAL
F16
DEVICE TYPE
MODIFY:0H
F21
PROCESS CONT VR
LOCAL ENABLE
F25
SERVO/AV REF SEL
IN PREREAD MODE
2-30
Settings
Description
[ON]
Turns on and off the Dolby NR when using a metal tape.
SW
ON: Dolby NR is turned on usually
SW: Dolby NR switch is turned on and off depending on the setting of the sub
control panel
m
. This item is used exclusively for analog Betacam longitudinal audio playback
adjustment for 625/50 system.
After adjustment is completed, return to the factory setting "ON".
. When using an oxide tape, follows the sub control panel switch setting
regardless of the above setting.
[ENA]
Selects whether emergency tape protection operation is enabled or not when VTR
DIS
detects error in tape transport mechanism.
ENA: Tape protection operation is enabled
DIS: Tape protection operation is disabled
n
This item is used exclusively for servo and mechanical adjustment.
After adjustment is completed, return to the factory setting "ENA".
[OFF]
Turns on and off the tracking control operation with search dial.
ON
OFF: Tracking control with the search dial is not activated
ON: Tracking control becomes active when turning the search dial in PLAY mode
n
This item is used exclusively for video tracking adjustment.
After adjustment is completed, return to the factory setting "OFF".
[0]
Determines response data to 9-pin remote command DEVICE TYPE REQUEST
1
(00h, 11h).
|
0:
FFFF
Except 0: Returns the set values as they are:
n
Any selection of the above does not influence the whole VTR operation including
TTP.
If this item is set to values other than the factory setting "0", the operation of the
unit is not ensured under the 9-pin remote command control.
[ON]*
Selects whether Process control (step menus, knobs, and switches) is enabled or
OFF
not, when LOCAL DISABLE command is received through the 9-pin remote
connector or the setup menu ITEM-006: LOCAL FUNCTION ENABLE is set to
"DIS" (all disable).
ON: Settings of above Process control are enabled
OFF: Settings of above Process control are disabled
n
*: When the SY1 ROM version is earlier than 1.33, the factory setting is "OFF".
[OFF]
Selects the reference servo signal during pre-read operation.
ON
OFF: The setting of ITEM-309 is enabled.
ON: The reference servo signal is set to forced EXT. (An external reference video
input signal is used in this case.)
Returns the original device type data of the unit
The higher-order two digits are for DATA-1
The lower-order two digits are for DATA-2
(Continued)