2-14. Fixtures and Adjustment Equipment List

2-14-2. Equipment for Adjustment

It is recommended to use the equipment listed below or the equivalents.
Each equipment is available as a standard product.
n
These equipment are used in the maintenance manual part 2.
Equipment
Analog composite video signal generator
(with GENLOCK mode)
Analog composite video signal generator
Analog component video signal generator
Digital component video signal generator
Spectrum analyzer
Oscilloscope
Analog component waveform monitor
Serial component waveform monitor
Analog composite waveform/vector monitor
Audio signal generator
Audio analyzer
Audio level meter
Frequency counter
Digital voltmeter
Monitor with serial digital input
Network analyzer
Time code generator
Time code reader
Terminator
BNC T adapter
Recording tape
Tension meter
2-26
Model name
Tektronix 1410
Tektronix 1411
Tektronix TSG-170A
Tektronix TSG-271
Tektronix TSG-300
Tektronix TSG-371
Tektronix TSG-422 (OP.1S)
Advantest R3261A
Tektronix 2465B
Tektronix WFM300 or WFM300A
Tektronix WFM601
Tektronix 1750 or 1780R
Tektronix 1751 or 1781R
Tektronix SG505 (OP.02)
Tektronix AA501A (OP.02)
Hewlett-Packard HP3400A
Advantest TR5821AK
Advantest TR6845
Sony BVM-1311
(with optional accessory BKM-2085-14)
Sony BVM-1411
(with optional accessory BKM-2085-14)
Anritsu MS420B
Sony BVG-1600
Sony BVG-1600PS
Sony BVG-1500
Sony BVG-1500PS
Sony BCT-SX series
Tentelo Meter T2-H7-UMC
Remarks
(For 525/60 system)
(For 625/50 system)
(For 525/60 system)
(For 625/50 system)
For generating SMPTE/EBU format analog
video signal
(For DNW-A75)
For generating SMPTE/EBU format analog
video signal
(For DNW-A75P)
For generating 4:2:2 format digital signal
With external trigger function
Bandwidth: more than 100 MHz
For measuring analog component video
levels
For measuring analog composite SC-H
(For 525/60 system)
For measuring analog composite SC-H
(For 625/50 system)
For measuring levels (dBm), distortion, and
dB ratio
(For DNW-A75)
(For DNW-A75P)
(For 525/60 system)
(For 625/50 system)
(For 525/60 system)
(For 625/50 system)
75-ohm, BNC type
75-ohm
Cassette tape for Betacam SX
For measuring tape tension