6.2.5 Logic board parameter forwarding
(1) The module is set according to the same to failure analysis procedure in clause 4.7.
The logic board before being exchanged is installed in the module.
(2) From the main menu, select change Logic board menu with the ↑ key or ↓ key and
press the <ENTER> key.
(3) From the logic board change menu, select data copy with the ↑ key or ↓ key and press
the <ENTER> key. Data is read before the Logic board is exchanged.
(4) The Logic board is exchanged.
Main menu
Logic board change menu