Cleaning Procedure
[Male connector]
Clean the tip of the white optical contacts with a cotton swab moistened with alcohol.
Optical contacts (white)
[Female connector]
The optical contacts for female connector are in an unexposed state. In cleaning, it is necessary to be exposed by removing
the alignment sleeve in advance. Proceed as follows.
1.
Insert the alignment sleeve remover into the alignment sleeve in the straight line and turn it clockwise.
Alignment sleeve
2.
When the turn stops, pull out the remover in the straight line forcedly.
Note
The alignment sleeve can be removed/reinstalled with the sleeve itself attached to the tip of the remover.
Great care should be taken so as not to lose or damage the alignment sleeve.
(Alignment sleeve: Sony P/N 9-980-074-01)
3.
Clean the tip of the white optical contacts with a cotton swab moistened with alcohol.
Alignment sleeve
4.
Insert the remover with the alignment sleeve attached to its tip, and push it until it clicks.
5.
Rotate the remover counterclockwise to install the alignment sleeve, and extract the remover.
[LC type connector]
Clean the tip of the white optical contacts with a cotton swab moistened with alcohol.
Cleaning connectors/cables of Tajimi Electronics Co., Ltd.
Clean the connectors and cables of Tajimi Electronics using the following procedure.
HDCU2500
Alignment sleeve
remover
Optical contact (white)
Optical contact (white)
Optical contacts (white)
1-35