5-2 Troubleshooting of Receiver

Symptom
All indicators are off.
Fault indicator (yellow) lights
or blinks.
Stable indicator (Orange)
lights up
OSSD indicator remains lit in
red (light is not received).
If the device does not work normally after checking the items above, please consult Panasonic
Industrial Devices SUNX.
<Indicators in the receiver>
Beam-axis alignment indicator
[RECEPTION]
OSSD indicator [OSSD]
Incident light intensity indicator [STB.]
Fault indicator [FAULT]
Digital error indicator
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Ramco Innovations | www.ramcoi.com | 800-328-6236 | nsales@ramcoi.com
Cause
Power is not being supplied.
Supply voltage is out of the
specified range.
Connector is not connected
securely.
[Digital error indicator: ]
Number of total units / num-
ber of total beam channels
error
[Digital error indicator: ]
Control output (OSSD 1 / 2)
error
[Digital error indicator: ]
Extraneous light error
[Digital error indicator: ]
External device monitor error
[Other than the above]
Effect from noise / power
supply or failure of internal
circuit
The beam channels of the
emitter and the receiver are
not correctly aligned.
The beam channels of the
emitter and the receiver are
not correctly aligned.
Number of total units / num-
ber of total beam channels
error
The master / slave setting is
different. (Beam synchroniza-
tion using 4-core cable)
<Blink cycle of the fault indicator>
Lights up
Blink cycle of
the fault indicator
Turns OFF
Remedy
Check that the power supply capacity is sufficient.
Connect the power supply correctly.
Provide the supply voltage within the specified
range.
Connect the connector securely.
Connect the end cap properly. Connect the cable
for series connection correctly.
Check the model (emitter / receiver) of sub sen-
sor exclusive for series connection.
Set the same value to the numbers of emitter and
receiver.
Connect the control output (OSSD 1 / 2) wire correctly.
Check the type of the bottom connector.
Cable of the receiver: Grey (with black stripe)
Prevent any extraneous light from entering the
receiver.
Connect the external device monitor input wire
correctly.
Replace the relay unit.
Replace the relay unit having appropriate re-
sponse time.
Check the noise status around this device.
Check the wiring, supplied voltage and power supply capacity.
When the synchronization cable is extended with
a cable other than exclusive cable, use a 0.2mm
or more shielded twisted pare cable.
Even if the error is not eliminated, contact Pana-
sonic Industrial Devices SUNX.
Align the beam channels.
Align the beam channels.
Set the same value to the numbers of emitter and
receiver.
Set the setting identically.
0.3
0.3
2 sec.
sec.
sec.
No. of blinks
2
No. of blinks
65