1-8. Settings of Internal Switches
S200-4 (A-5) : RS-232C/ISR Select switch
Selects the mode of the RS-232C control port.
ON : ISR mode
OFF : Normal operation
Factory setting: OFF (upper position)
n
After this setting is changed, turn the power off and on again.
S200-5 (A-5) : REMOTE/LOCAL Select switch
Selects whether the operation of the BDX-D1000 is
controlled by an external computer via Ethernet or by
using the menu and the buttons on the front panel.
ON : By an external computer via Ethernet
(REMOTE control)
OFF : By using the menu and buttons
(LOCAL control)
Factory setting: OFF (upper position)
n
When remote control mode is selected, it can not be
controlled from the front panel.
At this time, "
" is displayed on the PROGRAM
indicator and "
" is displayed on the AUDIO indicator.
S200-6 (A-5) : LNB Power Select switch
Selects whether or not the power is provided from the IF
terminal to the LNB (Low Noise Block).
ON : Power is provided from the IF terminal.
OFF : Power is not provided from the IF terminal.
Factory setting: OFF (upper position)
S300 (A-1) : Reset switch
n
Do not press this switch under normal conditions.
S302 (A-3) : Factory use
Factory setting: All switch levers are set to ON.
S600 (C-6) : Factory use
Factory setting: All switch levers are set to ON.
S800-1 to 3 (F-4) : Factory use
Factory setting: All switch levers are set to ON.
S800-4 (F-4) : Freeze time Select switch
Select the Freeze time in Freeze mode (S200-3 : ON)
ON : 525 Mode : 33 Frame
625 Mode : 39 Frame
OFF : 525 Mode : 16 Frame
625 Mode : 14 Frame
Factory setting : OFF (lower position)
1-10 (E)

1-8-3. DEC-99 Board (SUFFIX -11 through -13)

J
H
G
S600
F
E
D
C
B
S300
A
1
2
3
4
Factory setting
1 2 3 4 5 6
ON
n
. The addresses on the board are shown by ( ) marks.
. For the switches described "Factory use", do not change
the factory setting.
S200-1 (A-5) : 525/625 Select switch
Selects the video output mode.
ON : 525/60 Hz (NTSC) system
OFF : 625/50 Hz (PAL) system
Factory setting : ON (lower position)
n
After this setting is changed, turn the power off and on again.
S200-2, 3 (A-5) : Factory use
Factory setting : OFF (upper position)
Factory setting
S302
Factory setting
S200
5
6
7
8
A side (Component side)