Device Range That Can Be Set - Mitsubishi Electric GOT1000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

4.4 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit
of word device.
Displays the device type and setting range which are
Information
selected in [Device].
Description
4.4.1
OMRON PLC (OMRON
SYSMAC)
Device name
Setting range
I/O relay/internal
..000000 to ..614315
auxiliary relay (...)
Data link relay (LR)
LR00000 to LR19915
Auxiliary memory
AR00000 to AR95915
relay (AR)
Holding relay (HR)
HR00000 to HR51115
Internal auxiliary
relay/Work relay
WR00000 to WR51115
(WR)
Timer contact (TIM)
TIM0000 to TIM4095
Counter contact
CNT0000 to CNT4095
(CNT)
Specified bit of the following
word devices
(except data link relay,
*1*4
Word device bit
auxiliary memory relay,
holding relay
and internal auxiliary relay.)
I/O relay/internal
..0000 to ..6143
auxiliary relay (...)
Data link relay (LR)
LR000 to LR199
Auxiliary memory
AR000 to AR959
relay (AR)
Holding relay (HR)
HR000 to HR511
Internal auxiliary
relay/Work relay
WR000 to WR511
(WR)
Data memory (DM)
DM00000 to DM32767
Timer (current value)
TIM0000 to TIM4095
*3*5
(TIM)
Counter (current
CNT0000 to CNT4095
*3*5
value) (CNT)
Extension data
memory (EM current
EM00000 to EM32767
*2
bank)
Extension data
E000000 to E032767
memory (E0 to EC:
*2
EC00000 to EC32767
13banks)
*1
When executing the touch switch function set during the bit
specification of the word device, do not write any data to the
word device through the sequence program.
*2
Writing or reading the extension data memory using multiple
banks is not allowed.
*3
Timer (current value) and counter (current value) are valid
within the range of 0 to 9999.
(This applies to the 16 bit/32 bit device data.)
*4
This is not supported by GT10.
*5
"Timer (current value)" and "Counter (current value)" are
handled as BCD values by the PLC.
If the connection form between the PLC and the GOT is
serial, however, they are handled as unsigned binary 16-bit
data by the GOT. Set the data type of "Monitor object" in the
GOT to "Unsigned BIN16".
4. CONNECTION TO OMRON PLC
4.4 Device Range that Can Be Set
Device No.
representation
Decimal +
Hexadecimal
Decimal
-
Decimal
:
4 - 41
1
2
3
4
5
6
7
8