Supply And Distribution Circuit Board (Only Cps21T With Keypad) - Bosch CPS21T Connectivity Manual

Industrial-pc
Table of Contents

Advertisement

Interfaces
6–4
6.3

Supply and distribution circuit board (only CPS21T with keypad)

Supply and distribution circuit board
1
X24
3
1
X25
4
1
X26
4
1
X27
4
The supply and distribution circuit board in the CPS21Twith the keypad must
in any case be wired. Here, the following are to be connected:
D 24 VDC power connection
D all keys on the front panel
(START, STOP, EMERGENCY-STOP)
D Distributor "key sodes" on the front panel
X29 is not used when the external distributor cable is directly connected
with the "V24Out" connector on the PC!
X24
1
2
3
X25
1
2
3
4
X26
1
2
3
4
X27
1
2
3
4
DANGEROUS ELECTRICAL VOLTAGE
Risk to life and considerable material damage due to faulty or not
professionally installed EMERGENCY-STOP circuit!
Also integrate the EMERGENCY-STOP button of the CPS21T with the
keypad in the EMERGENCY-STOP circuit!
Connector START key
24 V for lamp in the START key
24V
terminal
24V
power supply cable
0V
0V
24V
Internal connection to
24V
X10_1
0V
0V
24V
24V
for free availability
0V
0V
1070 073 826-101 (01.10) GB