Safety instructions for installation

Risk of damage from incorrect installation.
Incorrect installation can cause damage to the cooktop.
The cooktop must only be installed by a qualified person.
Danger of electric shock!
Incorrect connection to the power supply may result in an electric shock.
The cooktop must be connected to the power supply by a qualified electrician.
Damage from falling objects.
Take care not to damage the cooktop when fitting wall units or a rangehood
above it.
Fit the wall units and the rangehood before the cooktop.
The veneer or laminate coatings of worktops (or adjacent kitchen
units) must be treated with 100 °C heat-resistant adhesive which will
not dissolve or distort. Any splashbacks must be of heat-resistant
material.
The cooktop must not be installed over a fridge, fridge-freezer,
freezer, dishwasher, washing machine, washer-dryer or tumble dryer.
A gas cooktop must not be installed adjacent to this cooktop.
This cooktop must not be installed above ovens unless these
have a built-in cooling fan.
After installation, ensure that nothing can come into contact with
the connection cable and that it is without hindrance.
The connection cable may not come into contact with any moving
kitchen component (e.g. a drawer) or be subject to mechanical
obstruction which could damage it.
Carefully observe the safety clearances listed on the following
pages.
11464020-02
Installation

Advertisement

Table of Contents
loading

Summary of Contents for Miele KMDA 7633 FR

  • Page 1 *INSTALLATION* 11464020-02 Installation Safety instructions for installation  Risk of damage from incorrect installation. Incorrect installation can cause damage to the cooktop. The cooktop must only be installed by a qualified person.  Danger of electric shock! Incorrect connection to the power supply may result in an electric shock. The cooktop must be connected to the power supply by a qualified electrician.
  • Page 2 *INSTALLATION* 11464020-02 Installation  All ducting, pipework and fittings must be of non-flammable material and comply with all relevant national and local building regulations.  The appliance must not be connected to a chimney or vent flue which is in current use for exhausting fumes from appliances burning gas or other fuels.
  • Page 3 *INSTALLATION* 11464020-02 Installation Safety distances Safety distance above the cooktop The safety distance specified by the manufacturer of the rangehood must be maintained between the cooktop and the rangehood above it. If the manufacturer's instructions are not available for the rangehood, a minimum safety distance 600 mm must be maintained.
  • Page 4 *INSTALLATION* 11464020-02 Installation Safety distances to the sides and back of the appliance The minimum distance shown below must be maintained between the back edge of the cooktop and a tall unit or wall. Ideally the cooktop should be installed with plenty of space on either side.
  • Page 5 *INSTALLATION* 11464020-02 Installation Tiled worktop Installation notes All dimensions in this instruction booklet are given in mm. Surface-mounted installation Seal between the cooktop and the worktop Grout lines  and the hatched area underneath the cooktop frame must be smooth and even. If they are not, the cooktop will not sit flush with the worktop and the sealing strip underneath the cooktop will not provide...
  • Page 6 *INSTALLATION* 11464020-02 Installation Flush-fit installation Natural stone worktops The cooktop is placed directly in the Flush-fit installation is only possible in cut-out. natural stone (granite, marble), solid wood and tiled worktops. When using Solid wood worktops, tiled worktops, a worktop made from any other glass worktops material, please check first with the The cooktop is placed on a wooden...
  • Page 7 *INSTALLATION* 11464020-02 Installation Installation examples Recirculation mode Extraction mode...
  • Page 8 *INSTALLATION* 11464020-02 Installation a Front Installation dimensions – Surface-mounted b Removable drip tray c Mains connection box with mains KMDA 7633 FR, KMDA 7634 FR connection cable, L = 1440 mm d Air duct connection – at the back (ex-works) e Air duct connection - on the right (conversion required) f Air duct connection - on the left (conversion required)
  • Page 9 *INSTALLATION* 11464020-02 Installation KMDA 7633 FL, KMDA 7634 FL a Front b Removable drip tray c Mains connection box with mains connection cable, L = 1440 mm d Air duct connection – at the back (ex-works) e Air duct connection - on the right (conversion required) f Air duct connection - on the left (conversion required)
  • Page 10 *INSTALLATION* 11464020-02 Installation Worktop depth 600 mm KMDA 7633 FL, KMDA 7634 FL KMDA 7633 FR, KMDA 7634 FR a Housing unit back panel The housing unit back panel must be a Housing unit back panel removable for service work. The The housing unit back panel must be housing unit wall and an adjoining removable for service work.
  • Page 11 *INSTALLATION* 11464020-02 Installation Extraction to the rear (standard) Extraction to the right Extraction to the left...
  • Page 12 *INSTALLATION* 11464020-02 Installation Worktop depth greater than 600 mm KMDA 7633 FL, KMDA 7634 FL KMDA 7633 FR, KMDA 7634 FR a Housing unit back panel The housing unit back panel must be a Housing unit back panel removable for service work. The The housing unit back panel must be housing unit wall and an adjoining removable for service work.
  • Page 13 *INSTALLATION* 11464020-02 Installation Extraction to the rear (standard) Extraction to the right Extraction to the left...
  • Page 14 *INSTALLATION* 11464020-02 Installation a Front Installation dimensions – Flush b Removable drip tray KMDA 7633 FL, KMDA 7634 FL c Mains connection box with mains connection cable, L = 1440 mm d Stepped cut-out e Wooden frame (to be provided on site) f Air duct connection – at the back (ex-works) g Air duct connection - on the right (conversion required)
  • Page 15 *INSTALLATION* 11464020-02 Installation Worktop depth 600 mm KMDA 7633 FL, KMDA 7634 FL a Housing unit back panel The housing unit back panel must be removable for service work. The housing unit wall and an adjoining room wall or furniture housing must be at least 110 mm apart to ensure sufficient room for the ducting.
  • Page 16 *INSTALLATION* 11464020-02 Installation Extraction to the rear (standard) Extraction to the right Extraction to the left...
  • Page 17 *INSTALLATION* 11464020-02 Installation Worktop depth greater than 600 mm KMDA 7633 FL, KMDA 7634 FL a Housing unit back panel The housing unit back panel must be removable for service work. The housing unit wall and an adjoining room wall or furniture housing must be at least 110 mm apart to ensure sufficient room for the ducting.
  • Page 18 *INSTALLATION* 11464020-02 Installation Extraction to the rear (standard) Extraction to the right Extraction to the left...
  • Page 19 *INSTALLATION* 11464020-02 Installation Changing extraction direction If you modify the extraction direction, the original brackets will no longer be required.  Use the brackets supplied separately with the extractor once the extraction direction has been modified.  Undo the fixing brackets. Keep the original brackets in case the extraction direction needs to be modified again.
  • Page 20 *INSTALLATION* 11464020-02 Installation Extraction to the left  Place the cooktop on its ceramic surface on a soft underlay.  Rotate the fan by 90°.  Secure the fan (you only need 4 screws). Make sure that the plastic  Release the 4 catches and remove edge is on the left.
  • Page 21 *INSTALLATION* 11464020-02 Installation  Use the bracket supplied separately to secure the fan.  Place the drip tray onto the extractor  Slide the frame outwards towards the again and secure the tray using the current extraction direction and tilt up 4 catches.
  • Page 22 *INSTALLATION* 11464020-02 Installation Connection to window contact, if required  The window contact is connected to the mains voltage! Danger of electric shock! Disconnect the cooktop from the mains electricity supply before connecting the switching mechanism. The connection cable of the switching system must only be connected by a suitably qualified and competent electrician.
  • Page 23 *INSTALLATION* 11464020-02 Installation  Exchange the jumper  with the connection cable of the switching system.  Close the casing.  Tighten the strain relief screw.  Reinsert the plug.
  • Page 24 *INSTALLATION* 11464020-02 Installation Surface-mounted installation  Create the worktop cut-out. Remember to maintain the minimum safety distances (see “Installation – Safety distances”).  Seal the cut surfaces of wooden worktops with a suitable sealant to avoid swelling caused by moisture. The sealant must be heat-resistant.
  • Page 25 *INSTALLATION* 11464020-02 Installation Flush-fit installation  Create the worktop cut-out. Remember to maintain the minimum safety distances (see “Installation – Safety distances”).  Solid wood, tiled and glass worktops: Fix a wooden frame 5.5 mm below the top edge of the worktop (see the diagram in “Installation”...
  • Page 26 *INSTALLATION* 11464020-02 Installation Exhaust ducting Remember that any constriction of the airflow will reduce extraction  If the extractor is used at the performance and increase operating same time as a heating appliance noise. that relies on oxygen from the same room, there is a risk of toxic fumes.
  • Page 27 *INSTALLATION* 11464020-02 Installation  If the exhaust air is to be ducted into a flue, the ducting must be directed in the flow direction of the flue.  If ducting is to be laid horizontally, it must be laid with a downwards sloping gradient.
  • Page 28 The connection data is quoted on the and repairs can be dangerous to data plate. Please ensure this users. information matches the household Miele cannot be held liable for mains supply. damage or injury caused by incorrect Please see the wiring diagrams for or unauthorised installation, connection.
  • Page 29 When replacing the mains connection cable, it must be replaced with cable type H 05 VV-F by a Miele authorised service technician or a suitably qualified and competent electrician in order to avoid a hazard. These cables are...