Mitsubishi Electric 800 Series Instruction Manual page 111

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Instance attribute
No.
1
Status
2
Configuration Capability
3
Configuration Control
Physical Link Object
Path size
4
Path
Interface Configuration
IP Address
Network Mask
5
Gateway Address
Name Server
Name Server 2
Domain Name
6
Host Name
Encapslation Inactivity
13
Timeout
• Status (Attribute 1)
Bit
0 to 3
Interface Confiugration Status
4
5
Interface Configuration Pending
6 to 31
• Configuration Capability (Attribute 2)
Bit
0
BOOTP Client
1
DNS Client
2
DHCP Client
3
DHCP-DNS Update
4
Configuration Settable
5
Hardware Configurable
Interface Configuration Change
6
Requires Reset
7
AcdCapable
8 to 31
• Configuration Control (Attribute 3)
Bit
0 to 3
Configuration Method
4 to 31
110
2. Ethernet Communication
2.11 EtherNet/IP
Name
Access
Get
Get
Set
Get
Set
Set
Set
Name
How to configure Attribute 5
0: Not configured
1: Configured by setting parameters, BOOTP, DHCP
2: Configured by hardware setting
Fixed to 0
Attribute 5, setting change during pending.
"1" is set when inverter reset is required to enable the setting change.
Fixed to 0
Name
0: Not supported
1: Supported
0: Not supported
1: Supported
0: Not supported
1: Supported
Fixed to 0
Attribute 5, access condition
0: Setting not allowed
1: Setting allowed
Attribute 5, hardware configuration condition
0: Setting not allowed
1: Setting allowed
Attribute 5, change application condition
0: Immediately
1: After reset
0: Not supported
1: Supported
Fixed to 0
Name
Network setting acquisition method after startup of the inverter
0: Parameter setting
1: BOOTP
2: DHCP
Fixed to 0
Type
DWORD
Refer to "Status (Attribute 1)" on
80 (0050h):
DWORD
Refer to "Configuration Capability (Attribute 2)" on
DWORD
Refer to "Configuration Control (Attribute 3)" on
Structure
Path size and Path
UINT
0002h
Padded
20 F6 24 03h
EPATH
Structure
TCP/IP interface setting
UDINT
IP address (Pr.1434 to Pr.1437)
UDINT
Subnet mask (Pr.1438 to Pr.1441)
UDINT
Default gateway (Pr.442 to Pr.445)
UDINT
Fixed to 0
UDINT
Fixed to 0
STRING
Fixed to 0
STRING
Host name
0: Inactive
1 to 3600 s: TCP connection timeout after the message is
UINT
received
(Initial value: 120 s)
Description
Description
Description
Description
page
110.
Path to Ethernet Link Object
page
110.
page
110.